20
8. WARNINGS
Attention: Before attempting any job on the control board (connections, maintenance), cut out electric power and the
battery.
-Install, upstream of the system, a differential thermal breaker with adequate tripping threshold.
-Always separate 230VAC power cable from control and safety cables (push-buttons, receiver, photocells, etc.). To avoid
any electric noise, use separate sheaths or a shielded cable (with earthed shield).
P1
Programming push-button: "Function"
P2
Programming push-button: "Value"
F1
Battery and motor fuse F20A
J1
Accessories terminal board
J2
Transformer terminal board
J3
Motor connection terminal board
J4
Battery connector
J5
Minidec/RP Receiver connector
10. MASTER-B BOARD LAYOUT
F1
Battery and motor fuse F20A
J2
Bus connection terminal board
J3
Motor connection terminal board
J4
Battery connector
9. SLAVE-B BOARD LAYOUT
J1, J5, P1, P2 and LED are not present on the SLAVE-B board,
and the other elements have the following functions.
Fig. 7
12 Vac
transformer
(optional)
12V battery
Voltage ON and
diagnostics LED
( LED P )
Programming LED
P2
P1
J2
F1
J4
J1
J3
J2
F1
J4
J3
J5
SLAVE-B EQUIPMENT
MASTER-B EQUIPMENT
*
Note:
if not using the transformer supplied by FAAC, make sure that the secondary winding is 12Vac - 16VA.
*