![background image](http://html1.mh-extra.com/html/faac/e045/e045_manual_3114545014.webp)
E045
14
732786 - Rev.C
DL12
DL11
DL12
DL11
RADIO 433-868
J5
24V ERROR
DL13
DL17
DL16
5V
ERROR
4V E
2
E
5V
ERR
5V 24V E
24 EERR
4V E
ENGLISH
LED
ON
FLASHING
OFF
DL1
Power present
Communication present
Power present
Communication absent
Power
absent
Communication absent
DL1 must always be on to confirm correct encoder/board connection.
DL2
Leaf 1
/
Leaf 2
DL2 indicates the leaf on which the encoder is installed; it must be on for leaf 1 and off for
leaf 2.
DL3
Stationary leaf
Leaf in motion
Stationary leaf
DL3 indicates pulse reading during leaf movement using steady flashing. In stationary status
of the leaf, the DL3 can be either on or off.
In case of incorrect connection (DL2 on or off for both of the encoders), during the
BUS-2EASY
accessories learning procedure, the DL1 leds of both encoders are
FLASHING.
Tab.
BUS-2EASY
Encoder LEDs Status
4.7 J5 -
XF
MODULE RAPID CONNECTOR
Plug-in rapid connector dedicated to
OMNIDEC
2-channel decoding module.
ALWAYS cut off power to the board BE-