8. SIGNALLING ERRORS AND ALARMS
In case of
ERRORS
(conditions that stop gate operation) or
ALARMS
(conditions that do not
compromise gate operation) the display will show the number corresponding to the warning in progress
by simultaneously pressing
+
and
-
.
These warnings will disappear in the following cycle only if the situation causing them is
removed.
8.1
ERRORS
When there is an ERROR the ERROR LED will go on steady. By simultaneously pressing
+
and - the display will show the corresponding error number.
The following table contains all the errors that can be viewed on the display
.
N°
ERROR
SOLUTION
0 1
Board broken
Replace the board
0 5
Invalid SETUP
Repeat board SETUP
0 8
BUS-2EASY
device error
Ensure that no two pairs of devices have the same address.
0 9
BUS-2EASY
output
short-circuit
Check the connections of the connected and entered
BUS-2EASY
devices
1 2
BUS-2EASY
call
Ensure that the BUS devices are operating correctly and, if
necessary, repeat BUS device acquisition
1 3
FAIL SAFE
Check that the safety devices (photocells) are operating cor-
rectly
1 4
Configuration error
Check that the board is configured correctly (basic and advanced
programming) and, if necessary, repeat SETUP
1 7
Motor 1 encoder fault
Check the connections or replace motor 1 encoder
1 8
Motor 2 encoder fault
Check the connections or replace motor 2 encoder
1 9
Incorrect memory data
Repeat
BUS-2EASY
device entry and/or re-program the board