E045
22
732786 - Rev.C
ENGLISH
Display
Advanced Function
Default
PF
PRE-FLASHING:
You can enable/disable the pre-flashing. Pre-flashing duration = 3 sec.
Y
=
enabled before each movement
no
= disabled
no
EC
ANTI-CRUSHING SENSITIVITY (visualised only with the function
En
=
Y
):
Varying this function varies the amount of time after which, in case of obsta-
cle, the board commands reversal of the leaves, or it will command a stop
if the leaves are in the contact point search space (see the parameter
rB
).
The fourth consecutive obstacle detected in the same direction and position
will be defined as a contact point and the leaf will stop in that position.
00
= minimum sensitivity (maximum time before reversal)
10
= maximum sensitivity (minimum time before reversal)
05
r8
CONTACT POINT SEARCH ANGLE (visualised only with the function
En
=
Y
):
You can adjust the contact point search angle within which the board will stop
movement without reversing, if it encounters an obstacle or the contact point.
Adjustable in two modes:
01
= Low contact point search space (about 1 degree)
02
= High contact point search space (about 4 degree)
02
tA
ADDITIONAL OPERATING TIME (displayed only if function
En
=
no
):
You can add a work time at the end of movement.
Adjustable from
0
to
30
sec in 1 sec steps.
This time is not considered when calculating the deceleration per-
centage.
03