E045
10
732786 - Rev.C
ENGLISH
4.4 J9 - ACCESSORIES POWER SUPPLY
15
-
GND Accessories power supply negative
16
17
+
+24 Accessories power supply positive (MAX. load = 500mA)
18
4.5 J11 - INDICATOR LIGHT/ELECTRIC LOCK OUTPUTS
20
W.L.
Indicator Light
Output
24 V
"
- MAX
Load
100mA
21
LOCK
Electric lock (12 V~ or 24 V
"
)
operated 2 sec before opening
of
leaf 1
When
BUS-2EASY
encoder is
disabled
, the electric
lock is operated before each opening (in whatever
position the leaf is in).
When
BUS-2EASY
encoder is
enabled
, the electric
lock is operated before opening, only if the leaf is
closed position.