A
B
E045
13
732786 - Rev.C
GATECODER
S800 ENC
J10
BUS-2EASY
DL1
DL2
DL3
DL1
DL2
DL3
J10
BUS-2EASY
DL3
DL2
DL1
DL3
DL2
DL1
DL1
DL2
DL3
M2
DL1
DL2
DL3
M1
DL1
DL2
DL3
M2
DL1
DL2
DL3
M1
ENGLISH
BUS-2EASY
encoder
BUS-2EASY
encoder connection is done using the bi-polar cables supplied with.
Connection - Address assignment of
BUS-2EASY
Encoder
The polarity of the
BUS-2EASY
line connection determines the correspondence of the
encoder to one leaf or the other.
pay careful attention to the indications of the status LEDs located on the body of each
encoder.
LEAF 1 opens first and closes last.
M1
: 2 LEDs on
M2
: 1 LED on
·
·
Note
: to correct the coupling of the
encoder with motor M1 or M2, swap both
wires on the terminals.
Summary of Contents for E045
Page 1: ...E045 E045...
Page 43: ......