A952 90
532310 - Rev.A
16
Maintenance of other components
Low traffic
(up to 10 cycles/h)
Medium traffic
(10-100 cycles/h)
High traffic
(over 100 cycles/h)
STRUCTURES
Check the structures and the parts of the building to which the
door and the automation is fixed: make sure there is no damage,
cracking, breaks or subsidence.
Follow the manufacturer's instructions
DOOR FRAME
Check the frame: make sure that it is fixed correctly, that it is integral
and that there is no deformation or damage. Tighten screws and
bolts where necessary.
Follow the manufacturer's instructions
Check the leaf: that it is integral and that there is no deformation
or damage.
Follow the manufacturer's instructions
Check the hinges: make sure that they are fixed correctly, that they
are integral, correctly positioned in their seats and that there is no
deformation or damage.
Follow the manufacturer's instructions
Lubricate hinges or locks, if necessary.
Follow the manufacturer's instructions
Generally clean of the area of movement of the door.
24 months
12 months
6 months
Make sure that the pictograms are present and intact. If they are
missing or damaged, replace them
24 months
12 months
6 months
FUNCTION SET-UP SELECTOR AND KEYBOARD
Check that they are intact and operating correctly.
24 months
12 months
6 months
PROTECTIVE DEVICES AND CONTROL DEVICES
Check that the protective devices are intact and that they operate
correctly.
Follow the manufacturer's instructions
Check that the control devices are intact and that they operate
correctly.
24 months
12 months
6 months
Check that the pictograms that identify the control devices for
disabled persons are present and intact.
24 months
12 months
6 months
Check that the door operates properly in both directions with all
the devices installed.
24 months
12 months
6 months
Check that the door moves smoothly and uniformly without making
any unusual noises.
24 months
12 months
6 months
Check that the opening and closing speed is correct. For doors in
“LOW ENERGY” mode, make sure that the opening and closing times
are within the limits permitted by the regulations
24 months
12 months
6 months
For doors in “LOW ENERGY” mode, make sure that it is possible to
stop the movement of the door without excessive force (Max. 67
N) at any point along its travel
24 months
12 months
6 months
Make sure that the manual opening force does not exceed 150 N
measured at the end of the leaf at a height of 1 m from the ground
24 months
12 months
6 months
Check that the door operates correctly in every operating mode.
24 months
12 months
6 months
“Check that the safety functions are working correctly (door reverses
or stops when an obstacle is detected, the door stops in the open
position when there is an obstacle in the area of movement etc.)”
24 months
12 months
6 months
Check that the CE marking and the DANGER AUTOMATIC MOVEMENT
warning sign on the door are present, intact and legible
24 months
12 months
6 months