A952 50
532310 - Rev.A
EMERGENCY CLOSE
When the input is activated, the
automation closes and remains closed as long as the
emergency is active.
FIRE ALARM
When the input is activated, the automa-
tion is closed with the lock released.
FIRE ALARM 2
When the input is activated, the auto-
mation closes with the lock engaged.
■
OVERHEAD PRESENCE SENSOR FUNCTION INPUT
When the input is active:
-
if the door is closed, it prevents it from opening
-
if the door is open, it prevents it from closing
-
this input is ignored during an opening/closing
movement
■
TIMER FUNCTION INPUT
TIMER
When the input is activated, TIMER program-
ming is enabled, which automatically assigns the op-
erating mode to the programmed time bands. When
the input is deactivated, the TIMER programming is
disabled.
RESET INPUT
RESET
When the input is activated, the board carries
out a RESET.
■
OPERATING MODE INPUTS
These
These inputs allow an operating mode to be selected:
ALWAYS OPEN, EXIT ONLY, ONLY IN, NIGHT, MANUAL, PARTIAL,
INTERLOCK.
■
SAFETY INPUTS
L
Use monitored safety devices that are compliant
with standard EN 16005:2012 on inputs configured
for safety functions.
On the inputs configured as Safeties, the Test to make
sure that the automation works correctly must be
enabled before movement takes place. If the test
fails, movement is inhibited (TEST ERROR).
CLOSING SAFETY
Connect the closing safety devic-
es. This input is activated:
-
If the door is closing, it reopens
-
If the door is already open, it prevents it from
closing If the door is opening, it has no effect
OPENING SAFETY
Connect the opening safety devic-
es. This input is activated:
-
If the door is opening, it stops until it is released
-
If the door is already closed, it prevents it from
opening
-
If the door is closing, it has no effect
■
DISABLING AN INPUT
DISABLED
When the input is disabled, it no longer
has any effect on operation, regardless of its status.