A952 76
532310 - Rev.A
OTHER BOARD DATA
The display indicates useful diagnostics information in real-time.
7 INTERCOM
FUNCTION
Sets the operating mode.
PRIMARY/SECOND. NR.
Sets the network ID of the unit.
INTERCOM REG.
Registers the units of the network (to be performed only on the
950N2 with ID1).
NODE LIST
Shows the ID of the registered units (on the PRIMARY).
8 MISCELLANEUS
DEFAULT CONFIG
ACTIVE: the programming corresponds to the DEFAULT settings
NO: the programming does not correspond to the DEFAULT
settings. To reload the DEFAULT settings press OK. The following
question appears:
DO YOU WANT TO RELOAD DEFAULT CONFIG?
Press OK to confirm.
BOARD'S DISPLAY
Allows programming from the board to be enabled/disabled.
NOT BLOCKED: programming from the board is enabled
BLOCKED: programming from the board is blocked
INTRUSION
DISABLED
ENABLED: the automation resists attempts to open it manually
or caused by gusts of air.
KP EVO KEY
Defines the operation of a key switch connected to the KP EVO:
BLOCK: KP EVO works with password when the contact is open
and is locked when the contact is closed.
WITHOUT USER PSW: KP EVO works without password when
the contact is open and with password when the contact is closed
CONSECUTIVE OBST.
Defines the number of consecutive obstacle detections after which
the automation stops in an error state.
CLOSING: 0…10 (0 = no count)
OPENING: 0…10 (0 = no count)
TEST ERROR
Allows the movement to be activated at minimum speed (as op-
posed to movement inhibited) if there is a TEST ERROR on an input
configured as SAFETY.
ENABLED: movement at minimum speed
DISABLED: the door will stop in an error condition
DIMMER
Specifies the percentage brightness of the KP EVO display in standby
(10%…90%).
Summary of Contents for A952