A952 67
532310 - Rev.A
53
2-button combinations:
+
(
5 s)
LOCK / UNLOCK
Press for approximately
5 s to Lock/Release the keypad (the LEDs
turn on and then off)
+
(
5 s)
RESET
(the LEDs corresponding to the
Error flash until the buttons are pressed,
release when they turn off)
+
(
.
..
)
WARNINGS
To display the active warn-
ings, press and hold the buttons (the
LEDs corresponding to the warning
flash as long as the buttons are pressed,
release when they turn off) (see
LED
Warning coding)
+
(
.
..
)
FW VERSION LK EVO
press and hold
the buttons to display the FW version of
the LK EVO (
LED FW version coding)
Total two-direction automatic
Door open
Automatic total one-direction
Automatic partial two-direction
Night
Manual
Icons Led (operating mode active)
Buttons
4
LED Error Coding LK EVO - KS EVO
Errors
1 Board failure
4 Accessories power supply
fault
Emergency input active
5 FW fault
7 Motor fail
9 Power supply fault / No mains
power
Input configured as safety test
failed
15 SETUP inhibited
16 Encoder fault
19 Friction too high
22 Programming data corrupted
24 Consecutive obstacles in closing
25 Lock fault
27 Motor rotation fault
31 Consecutive obstacles in opening
39 SETUP incorrect / missing
5
LED Warning coding - LK EVO
Warnings
44 Emergency input active
51 Obstacle detected when
closing
52 Obstacle detected when
opening
56 Battery operation
60 Maintenance request
65 SETUP in progress
68 Failsafe failure, slow move-