A952 75
532310 - Rev.A
MENU 1 LANGUAGE
Select the language from the list provided.
MENU 2 PROGRAMMING
L
The menu is only accessible if the TECHNICIAN pass-
word has been entered (default 0000).
1 SIMPLY CONNECT
1:
Non-modifiable. Indicates that Simply Connect is available.
2 INPUTS / OUTPUTS
INPUTS IN1-IN8
Allows you to select the input and to assign the function and type
of contact (NO, NC).
If you configure and input as a SAFETY, you are required to set the
TEST: ENABLED/DISABLED
OUTPUTS O1-O5
Allows you to select the output and to assign the function and type
of contact (NO, NC).
The LIGHT option requires the time to be set: 1…90s
EXTERNAL SELECTOR
Allows you to select the operating mode associated with positions
1 and 2 of the selector on the side of the unit.
3 MOTION
OPENING
Allows you to program:
OPENING SPEED: level 1…10
SLOWDOWN:
OP. SLOWDOWN SPACE 0°…90° , OP. SLOWDOWN SPEED 1…3
STRENGTH: level 1…10
STRENGTH DURATION: 0.1…3.0 s
ACCELERATION: level 1…10
DECELERATION: level 1…10
CLOSING
Allows you to set the same parameters as found under OPENING.
4 TIMING
Allows you to program:
PAUSE TIME 0…30 s
PAUSE TIME P&G: 0…30 s
NIGHT PAUSE TIME: 0…240 s
NIGHT SENSOR DELAY: 0…240 s
5 MOTOR LOCK KIT
Allows you to program the way the lock operates (if installed).
FUNCTION
Defines operating modes in which lock is activated:
DISABLED, NIGHT, EXIT ONLY, NIGHT + MONODIR, ALWAYS
LOCK DELAY
Defines the opening delay time of the door to allow the lock to be
released, particularly the motorised ones: 0-60 tenths of a second.
RELEASE TYPE
Specifies when power is disconnected from the lock after it has been
mechanically released.
OPENING: during opening
CLOSED: when the door is closed again
6 INSTALLATION
ARM TYPE
Defines the type of application (see
1 -
7) :
SKID 1
SKID 2
ARTICULATE
SPRING ACTION
Set the function of the spring (determined by the type of instal-
lation):
CLOSING SPRING
OPENING SPRING
START SETUP
Follow the instructions in the § SETUP section. Confirm to carry
out the SETUP.
PUSH AND GO
Sets the function that commands the motorised opening of the door
after an initial manual push:
DISABLED
ENABLED: Standard PUSH AND GO enabled (an initial manual
push commands motorised opening)
POWER ASSIST: PUSH AND GO enabled in “POWER ASSIST” mode
(reduces the resistance when opening the door to make it easier to
operate by hand)
PARTIAL STOP SEC.
Defines the detection area of the opening safety:
DISABLED: obstacle detection active over the entire opening stroke
ENABLED: obstacle detection NOT active in proximity to the open-
ing stop (the point at which it is disabled is memorised during SETUP
when the sensor detects an obstacle the first time during opening,
for example the wall towards which the door opens).
LEAF DELAY
Specifies the opening delay between the doors in 2-leaf
mode: 0°…90°.
SCP (selectable close power)
DISABLED
ENABLED: increases the force with which the door pushes in the
final section of the closure
REVERSE STROKE
DISABLED
ENABLED:
Commands a reverse stroke before opening to facilitate
the opening of the lock
2 EASY REG.
Confirm to register
BUS 2easy devices.
INOUT STATE
The display indicates the status (on / off) of inputs IN1-IN8 and
outputs O1-O5 in real-time.
DOOR STATUS
The display indicates the status of the automation in real-time.
Summary of Contents for A952