26
FAAC MODEL 950 BM Door Operator
TROUBLESHOOTING
PROBLEM
SUGGESTION
Operator will not run the setup cycle
1. Check that LED 5, 6 & 7 are ON
These LED’s show safety and stop circuits. Refer to
page 6 “installing jumpers” for more Information.
2. Insure that you hold down the setup button for a
minimum of 5 seconds Refer to page 6 “running the
setup cycle” for more information.
Door will not automatically close
1. Check that LED 2, 3, 4 & 8 are OFF
These LEDS show activation inputs, if an LED is ON
check the associated input to the LED and test devices
or refer to the activation device manual.
2. Check that LED 5, 6 & 7 are ON
These LED’s show safety and stop circuits. Refer to
page 6 “installing jumpers” for more information.
Door will not open
1. Check that LED 5, 6 & 7 are ON
These LED’s show safety and stop circuits. Refer to
page 6 “installing jumpers” for more information.
2. Check the activation device to see if the corre-
sponding LED goes ON
Door is hard to open manually
1. Reduce spring tension
Refer to page 5 “adjusting the spring”.
Door will not reach it’s full closed
position
1. Check the stop position against the closed position of
the door Refer to page 5 “adjusting the stops”.
2. Reduce spring tension
Refer to page 5 “adjusting the spring”.
I see a flashing red LED
1. This is showing you an alarm condition, please refer
to the complete manual.