FAAC MODEL 950 BM Door Operator
14 STOP Safety Command - N.C. Contact
Any device (safety sensor, photocell, etc.) which, by opening a
contact, has a safety effect on the operating cycle. In particular,
this safety device interrupts the opening/closing movement of the
door.
When the safety device is disengaged, the door resumes its
opening/closing movement and continues to the end of the cycle.
To install several STOP safety devices, connect the N.C. contacts
in series.
N.B.: If STOP safety devices are not installed, jumper inputs 7
and 13.
15 KEY Command - N.O. Contact
Any pulse generator (pushbutton, sensor, etc.) which, by closing
a contact, commands door opening.
To install several pulse generators as Internal Command, connect
the N.O. contacts in parallel.
16 FIRE-ALARM Command - N.O. Contact
Any device (fire-alarm sensor, etc.) which, by closing a contact,
commands door closing.
Permanence of the closed contact, inhibits operation of any other
pulse generator.
To install several devices as FIRE-ALARM Command, connect
the N.O. contacts in parallel.
17 CARD READER Command - N.O. Contact
Any device (card reader, digital buttonboards, etc.) which, by giving
a 24Vdc pulse, commands the door opening and the activation
of the changeover relay (terminals 20/21/22, J6 terminal board).
The open pause time is fixed at 10 sec.
18 - 19 GND
Accessories power supply Negative and contacts Common
7 8 9 10
1 2 3 4 5 6
J5
J4
max 0.5A/24Vdc
1 2 3 4 5 6
7 8 9 10
J5
J4
max 0.5A/24Vdc
1 2 3 4 5 6
DOOR OPEN
DOOR CLOSED
COM.
max 0.5 A/24 Vdc
15 16 17 18 19
CARD READER - 24Vdc Signal
C. R. Comand
GND
+
-
22 23 24 25 26
max 0.5 A/24 Vdc
ALARM
Output
ALARM Output
+24 Vdc
GND
Fig. 13
Fig. 14
Fig. 15
Fig. 16
Fig. 17
Fig. 18
Fig. 19
J4
J5
J6
J6
J6
25 26 27 28
Interlock Signal
2 Leaf Signal
20 21 22
Com. changeover Relay
N.O.
changeover Relay
N.C.
changeover Relay