FAAC MODEL 950 BM Door Operator

950 BM

Fig. 1

Cable pass through hole 

2

 

Support profile

950 I/O electronic control unit

4  Adjustment of internal mecha-

nical stops.

 

Transmission shaft coupling

Protection for drive system and 

re-closure spring.

 

DC motor

950 MPS programming unit

Toroidal transformer

10  Mains power terminal board.

11  Casing securing bracket

12  Earth lug

13   Power cable terminal

The 950 BM is an electro-mechanical automated system for swing-leaf 

doors with direct current motor and return spring. It has an integrated 

microprocessor control unit with self-diagnosis and continuous verifi

-

cation of all door functions and an anti-crushing safety device active 

for both opening and closing.

The activation arms is in stainless steel, and it can be pushing or sliding .

The 950 BM is able to do a self-learning procedure of  the open  and 

close positions and automatically measures the door weight for optimal 

operation.  An optional  “closing  stroke” function ensures that the door 

stays closed even under strong wind. It also has an optional “push 

and go” function and in case of power failure the door can be opened 

manually then closed with the help of the spring

1. DESCRIPTION AND TECHNICAL CHARACTERISTICS

1.1. APPLICATION LIMITS

Important

: To ensure correct application of the FAAC 950 BM unit the 

weight of the door must not exceed the value given in Table 3 referred  

to its length. The maximum length of the leaf is 55”. 

The values of maximum weight vary according to the driving arm used. 
For each driving arm there is also a different maximum value for the 

depth of the jamb (Table 4) beyond which it is not possible to install 

the system correctly. 

Pushing 

articulated 

arm

Sliding

 arm

 

0 - 9 

3/4

 

0 - 6 

1/4

 

inch

1

2

3

4

5

6

7

8

9

10

11

12

13

Power supply

 

115 Vac (+6 -10%) - 60 Hz  

Absorbed power

 

100 W

Absorbed current

 

1 A

Electric motor

 

24 Vdc with encoder

Dimensions

  

20 

3/4

 x 4 

1/8

 x 4 

3/4

 “ (length x height x depth)

Weight

                      22 lbs

Operating

 

ambient temperature 

-4 to 131 °F

Protection class 

 

IP 23 (internal use only)

Dimensions and leaf max weight

  

see Table 3 (paragraph 1.1)

Use frequency

 continuous

Operation in event of power failure

       Manual push/pull opening

Configuration of driving arms

  • pushing articulated arm 

                                                 (version for jamb depth 0  - 9 3/4” ) 

                                                   • sliding arm  (arm length 17”) 

Anti-crushing device    

 standard

Opening angle 

 

see table 5-6

Opening speed

  

4 to 10 s (adjustable)

Closing speed

 

4 to 10 s (adjustable)

Power supply

  

                              115  Vac (+6 -10%) - 60 Hz  

Accessories power supply

  

                  24 Vdc / 500mA max

Electric lock power supply (N.O./N.C.)

 

24 Vdc / 500mA max

Standard operating functions (selector switch)

         Open / Automatic 

                                                                                            Manual (Night)

Adjustable functions (trimmer) 

        Opening speed - Closing speed 

                                                                              Pause time 

Selectable functions (microswitches)

 

Closing stroke 

                                                           Standard/slide initialisation procedure 

                                              Push and Go - Function selector switch (pos.”2”)

                                                STOP safety device operation - RS232 port

Terminal block outputs

 

Malfunction alarm signal 

                                                Electric lock power supply (N.O./N.C) 

                                    24 Vdc accessories power supply - Door status signal 

                                           Changeover relay controlled by Card Reader 

                                          “Two-leaf door” signal - “Interlock” Signal

Terminal block inputs 

 

Internal / External Commands

     

                           Emergency Command - Key Command

                                       Card Reader Command - Fire-alarm Command  

                                       STOP Safety device - Closing Safety device

Rapid connectors                   

 KP-CONTROLLER (optional)

                                          Minidec Decoder or RP cards connection

                                            Functions selector switch connection   

Leaf length 

(inches)

Max leaf weight (lbs) 

Articulated arm

Max leaf weight (lbs) 

Sliding arm

27 

1/2

809

-

29 

1/2

705

-

31 

1/2

619

-

33 

1/2

548

428

35 

1/2

489

381

37 

1/2

438

342

39 

1/2

396

309

41

359

280

43

328

256

45

299

234

47

275

214

49

254

198

51

236

183

53

218

170

55

203

157

Table 3: Application limits of  950 BM operator

Table 4: Max jamb depth

Table 1: Technical specifications of 950 BM Operator

Table 2: Technical specifications of Control Board 950 I/O  

               and Control Board 950 MPS

(800) 878-7829

www.FastGateOpeners.com

Summary of Contents for 950 BM

Page 1: ...950 BM Swing Door Operator 800 878 7829 www FastGateOpeners com...

Page 2: ...2 FAAC MODEL 950 BM Door Operator shielded Fig 2a Fig 3 1 1 2 2 Fig 4 Fig 4b Fig 4a 3 1 4 1 4 3 2 2 6 5 5 8 8 7 800 878 7829 www FastGateOpeners com...

Page 3: ...3 FAAC MODEL 950 BM Door Operator Fig 5 Fig 6 800 878 7829 www FastGateOpeners com...

Page 4: ...he operator and the arm is required add the optional modular extensions Each modular extension increases the standard height of 1 1 8 inches It is not rccommended to use more than 2 extensions TABLE A...

Page 5: ...ween the operator and the arm is required add the optional modular extensions Each modular extension increases the standard height of 1 1 8 inches It is not rccommended to use more than 2 extensions T...

Page 6: ...24 Vdc with encoder Dimensions 20 3 4 x 4 1 8 x 4 3 4 length x height x depth Weight 22 lbs Operating ambient temperature 4 to 131 F Protection class IP 23 internal use only Dimensions and leaf max we...

Page 7: ...tor mounting position must not exhibit any significant deformation The operator must be mounted parallel to the floor NOTE Iftheslidingarmistobeused thedriving armmustbemounted before the operator is...

Page 8: ...d down SW1 button for at least 5 sec until the LD2 red LED on the 950MPS board lights up The LED will start flashing to indicate that SET UP process is in progress During this process the following pa...

Page 9: ...y obstacle e g side wall is prevented which would cause interruption of the work cycle 5 4 6 MICROSWITCH No 8 SCP Function SCP Function Selectable Close Power If the SCP function is enabled the door c...

Page 10: ...GND Accessories power supply Negative and contacts Common 9 24Vdc 24Vdc accessories power supply 10 Internal Command N O Contact Any pulse generator pushbutton sensor etc which by closing a contact c...

Page 11: ...h by closing a contact commands door closing Permanence of the closed contact inhibits operation of any other pulse generator To install several devices as FIRE ALARM Command connect the N O contacts...

Page 12: ...e side of the cover fig 4 ref 2 The selector switch position is fixed however depending on the type of installation on doorpost or on lintel the connection cable to the 950I O unit must be positioned...

Page 13: ...closing direction until the next fixing position of the stop point screw fig 21 ref 5 is in line with the inspection slot and fix the screw again 5 Reinstall the arm correctly see par 3 3 6 Run a new...

Page 14: ...x0 5mm max 50m cable Fig 24 If the two LOCK terminals are connected to each other as shown in Fig 24 all keys on the programmer are disabled 10 3 DIAGNOSTICS The KP Controller also without display has...

Page 15: ...ernal radars are disabled The Key command causes opening and closing after the night pause time elapses standard 7 sec Adjusting range of night pause time from 0 to 30 sec To obtain partial opening in...

Page 16: ...to select sub menu or parameter and confirm with the OK key An asterisk on the display indicates the currently active setting To exit programming select the exit function at each level Other wise afte...

Page 17: ...agram 3 Setup Diagram 4 Lock SETUP 80 7 SEC 2 SEC CLOSING STANDARD NO STANDARD OBSTACLE DETECTION NIGHT PAUSE TIME PARTIAL OPENING PAUSE TIME EXIT LOCK OFF ON ALWAYS ONE WAY NIGHT NIGHT KIT LOCK EXIT...

Page 18: ...NOSTICS NR CYCLE XXXX ALARM N alarm description PASSWORD 0000 PASSWORD 0000 PASSWORD 0000 PASSWORD 0000 KEEP SETTINGS OFF ON 8 8 EXIT ADVANCED MENU OPERATION PARAMETERS CLOSING SPEED OPENING SPEED cor...

Page 19: ...ASSWORD 0000 PASSWORD 0000 PASSWORD 0000 PASSWORD 0000 IN OUT SETUP EMERG OPEN CLOSE OUT OP CL NO OUT ALARM NO NC USCITA NC NO NC ADVANCED MENU OPERATION PARAMETERS VARIOUS EXIT CHANGE PASSWORD correc...

Page 20: ...SETUP STAND SETUP STANDARD NO STANDARD INTERLOCK MASTER SLAVE NO MEMORY WITH MEMORY EXIT NEW PASSWORD 0000 NEW PASSWORD 0000 NEW PASSWORD 0000 NEW PASSWORD 0000 MASTER SLAVE ON OFF ON OFF 2 LEAVES TES...

Page 21: ...UN 0 00 00 TIME BAND 3 FUN 0 00 00 TIME BAND 1 FUN 0 00 00 TIME BAND 2 FUN 0 00 00 TIME BAND 5 FUN 0 00 00 TIME BAND 4 FUN 0 00 00 TIME BAND 3 FUN 0 00 00 TIME BAND 1 FUN 0 00 00 TIME BAND 2 FUN 0 00...

Page 22: ...if the cause of signalled malfunction was removed it restores normal operation 5 ADVANCED MENU PASSWORD To access the advanced menu insert the 4 digit password default 0000 1 OPERATION PARAMETERS Dia...

Page 23: ...o 5 different time bands for each day of the week by setting the band starting time and assign an operational function to each time band When the KP Controller s internal clock reaches the starting ti...

Page 24: ...se totally in order to activate the sensor of the second door 6 Door B opens Fig 28 Door A Door B 7 The person exits 8 Door B closes after the night pause time elapses The operation is identical if th...

Page 25: ...ately reversed The partial opening function enables control of total opening of the master only The operating functions must be set on the master automated system only or on the KP Controller if conne...

Page 26: ...Check that LED 5 6 7 are ON These LED s show safety and stop circuits Refer to page 6 installing jumpers for more information Door will not open 1 Check that LED 5 6 7 are ON These LED s show safety...

Page 27: ...en subject to misuse neg ligence or accident or has not been operated in accordance with FAAC International Inc s or FAAC S p A s instructions or has been operated under conditions more severe than or...

Reviews: