5.2.

DESCRIPTION

5.2.1. J1 CONNECTOR

The J1 connector is used for rapid connection of cards
MINIDEC,DECODER, RP RECEIVERS (Fig. 16, 17, 18)
Install by fitting the accessory cards so that their components
side faces the inside of the 884 T control board.
Insert and remove the cards after cutting power.

5.2.2.  TERMINAL BOARD J2 (low voltage)

1 =

OPEN A (N.O.) – Total opening

This is any pulse generator with N.O. contact which, when
activated, produces a gate opening movement. In A, E
and S logics, it commands both opening and closing.
To install several Open A devices, connect N.O. contacts
in parallel.

2 =

OPEN B (N.O.) –  Pedestrian Opening / Closing

This is any pulse generator with N.O. contact which,  when
activated in A, E and S logics produces a gate opening
movement for pedestrians. In B and C logics, it commands
a closing movement.
To install several Open B devices, connect N.O. contacts
in parallel.

3 =

STOP command (N.C.)

This is any device (e.g. a push-button) which, by opening
a contact, stops gate movement.
To install several stop devices, connect the N.C. contacts
in series.

Ü

If Stop devices are not connected,  jumper the input to

the common (terminal 5).

4  =

FSW closing safety devices contact (N.C.)

Safety devices are all devices (photocells, sensitive edges,
magnetic loops) with N.C. contact, which, if there is an
obstacle in the area they protect, operate to interrupt
gate movement.  The purpose of the closing safety
devices is to protect the gate movement area during
closing.
If the safety devices are tripped during closing, gate
movement is reversed, whereas they have no effect
during opening. If engaged when the gate is open or
pausing, closing safety devices prevent its closing.
To install several safety devices, connect the N.C. contacts
in series.

Ü

If closing safety devices are not connected, jumper

this input to the common (terminal 5).

5 =

Common  for commands

6 =

Common  for powering accessories

7 =

Positive pole for powering 24 Vdc (+) accessories

Max load of accessories is 500 mA.
To calculate absorption values, refer to the instructions
for individual accessories.

9 =

Uscita lampada spia (Warning Light) 24 Vac

Il carico massimo della lampada spia è di 5W.
For instructions on operation of the indicator-light,
consult microswitch programming.

Ü

If you cut out  jumper LK1, you obtain a free contact

between terminals 8 and 9 (see fig.19).

COMPLETE LK1

INTERRUPTED LK1

(Free contact)

11 = Limit-switch common

12 = Opening limit-switch (N.O.)

13 = Closing limit-switch (N.O.)

5.2.3.  TERMINAL BOARD J3 (high voltage)

Terminal board for connecting flashing  lamp (max 60W).

5.2.4.  MORSETTIERA J4 (alta tensione)

Morsettiera per il collegamento del motore. Modificare i
ponticelli di collegamento motore (situati nella scatola di
derivazione sul lato destro del motore elettrico) in rapporto alla
tensione di alimentazione usata (vedi fig.14 e 15).

5.2.5.  MORSETTIERA J5 (alta tensione)

Morsettiera per l'alimentazione 400V 3ph + Neutro - 50 Hz (vedi
fig.14) oppure 230V 3ph - 50 Hz (vedi fig.15).
Collegare il cavo giallo/verde di terra come in Fig.20.

5.2.6. SIGNALLING LEDs

6 LEDs are fitted on the board, indicating status of terminal
board inputs:

L

ED

 

LIGHTED

 

 = contact closed

L

ED

 

OFF

  = contact open

TAB. 4

STATUS OF LEDS

LED

LIGHTED

OFF

OPEN A

command active

command inactive

OPEN B

command active

command inactive

STOP

command inactive

command active

FSW

safety devices not engaged

safety devices engaged

FCC

closing limit-switch free

closing limit-switch engaged

FCA

opening limit-switch free

opening limit-switch engaged

Summary of Contents for 884 mct

Page 1: ...t umweltfreundlich 100 Altpapier pour la nature papier recyclé 100 for nature recycled paper 100 per la natura carta riciclata 100 para la naturaleza 100 papel reciclado C ERME T A Z I E N D A C E R TIF I C A T A UNI EN ISO 9001 085 ...

Page 2: ...em s main switch 12 An omnipower switch shall be provided for the installation with an opening distance of the contacts of 3 mm or more Alternatively use a 6A thermomagnetic breaker with multi pole switching 13 Ensure that there is a differential switch up line of the electrical system with a trip threshold of 0 03A 14 Check that the earthing plant is in perfect condition and connect it to the met...

Page 3: ...ing gate By using a self braking motor the system is guaranteed to be mechanically locked when the motor is not in operation so a lock does not need to be installed The gear motors have adjustable mechanical clutches to ensure correct use of the automation A convenient manual release device allows the gatetobeopenedintheeventofapowerfailureormalfunction The electronic control unit is incorporated ...

Page 4: ... mount the pinion on the transmission shaft and fit the casing provided as shown in fig 6 4 4 MECHANICAL INSTALLATION 1 Remove the casing 2 fig 2 and position the gear motor on the foundation plate Fit but do not tighten the washer the split washer and the nut as shown in fig 7 2 Fit the adjustment screws on the gear motor base as shown in A fig 8 3 Adjust the height of the feet while keeping the ...

Page 5: ... with adequate tripping threshold Connecttheearthcabletotheappropriateseatontheoperator base see fig 20 The operator is equipped with a safety device fig 1 ref 7 activated by the release device If enabled it prevents any manoeuvre by the operator Observing the instructions in Fig 3 lay the raceways and make the electric connections of the 884 T control board to the selected accessories Always sepa...

Page 6: ...3 4 5 6 7 8 9 10 11 12 13 14 15 MOTOR LINE FCA FCC LAMP T1 T2 T3 N L1 L2 L3 400V 3ph N R S T M 3Ph 230 V MOTOR LINE T1 T2 T3 N L1 L2 L3 230V 3ph Fig 15 LED A LED OPEN LED B LED OPEN PARTIALLY CLOSE LED STOP LED STOP LED FSW LED SAFETY DEVICES LED FCC LED CLOSING LIMIT SWITCH LED FCA LED OPENING LIMIT SWITCH SW1 RESET PUSH BUTTON J1 DECODER CONNECTOR J2 LOW VOLTAGE TERMINAL BOARD J3 FAAC LAMP CONNE...

Page 7: ...ave no effect during opening If engaged when the gate is open or pausing closing safety devices prevent its closing To install several safety devices connect the N C contacts in series ÜIf closing safety devices are not connected jumper this input to the common terminal 5 5 Common for commands 6 Common for powering accessories 7 Positive pole for powering 24Vdc accessories Max load of accessories ...

Page 8: ...t GATE STATUS CLOSED OPEN IN PAUSE CLOSING OPENING STOPPED OPEN A OPEN B 1 opens and re closes after pause time 2 re closes after 5 3 reverses motion no effect re closes 2 TABLE 6 LOGIC A2 AUTOMATICA PLUS LOGIC S1 PULSES GATE STATUS CLOSED OPEN IN PAUSE CLOSING OPENING STOPPED OPEN A OPEN B 1 opens and re closes after pause time 2 closes immediately 2 3 reverses motion reverses motion re closes 2 ...

Page 9: ...late a further 10 mm and secure it provisionally on the rack by two weld spots 4 Manually take the gate to closing position leave it 5 cm from the limit stop 5 Allow the plate to slide over the rack in closing direction As soon as the FCC limit switch LED on the 884 T control board fig 13 goes off move the plate a further 10 mm and secure it provisionally on the rack by two weld spots Note The pla...

Page 10: ... A safety microswitch in the release system prevents the automation from being activated by accidental commands 7 fig 2 Close the door and open or close the gate manually 8 RETURN TO NORMAL OPERATION Open the door in the casing using the triangular key provided see fig 24 Move back the lever shown in fig 25 up to the mechanical stop pos AUTOMATIC Close the door 9 MAINTENANCE When performing mainte...

Page 11: ...for sliding gates is an electromechanical operator which transmits movement to the leaf by means of a pinion with rack or chain coupled in an appropriate manner to the sliding gate If automatic operation has been selected sending an impulse causes the gate to reclose on its own after the selected pause time If semiautomatic operation has been selected a second impulse must be sent to reclose the g...

Reviews: