Fig. 8

Min 10 mm

30 mm

Fig. 4

Z16 Mod.6

rif.A

Fig. 7

If the gear motor is located in a vehicle transit area, it is a
good idea to provide protection against accidental
collisions.

Check that the gear motor has an efficient earth connection.

4.2.

INSTALLING THE BASE PLATE

1) The base plate must be positioned as shown in Fig. 4.

For the positioning distances refer to fig. 5.

Important:

 The plate must be level with the middle of the pinion.

Remember to maintain a minimum distance of 10 mm between
the rack and the gate.

2) Assemble the foundation plate as shown in A, Fig. 4.
3) Prepare a foundation plinth as shown in Fig. 4 and install the

base plate providing one or more conduits for electrical
cables. Use a level to check that the plate is perfectly
horizontal and wait for the cement to set.

N.B.: 

It is advisable to install the plate slightly raised from the

ground. See A, fig. 9.

4) Set up the electrical cables for connection to the accessories

and the electricity supply as described in section 5. For ease
of connection, ensure that the cables protrude by about 1
m from the hole in the base plate.

4.3.

MOUNTING THE PINION

Before mounting the operator on the foundation plate, mount
the pinion on the transmission shaft and fit the casing provided
as shown in fig. 6.

4.4.

MECHANICAL INSTALLATION

1) Remove the casing (2, fig. 2) and position the gear motor on

the foundation plate. Fit, but do not tighten, the washer, the
split washer and the nut as shown in fig. 7.

2) Fit the adjustment screws on the gear motor base as shown

in A, fig. 8.

3) Adjust the height of the feet while keeping the gear motor

raised from the plate by 1 cm and maintaining the distance
from the gate shown in figs. 5 and 9.

4) Use a level to check that the operator is perfectly horizontal.

5) Tighten up the four securing nuts provisionally.

6) Set up the operator for manual operation as described in

section 7.

4.5

MOUNTING THE RACK

Important:

   To mount the rack on the leaf it is necessary to

construct special supports specifically for the type of gate. Fig.
10 shows an example of "L" support. For positioning the supports
refer to figs. 5 and 9.

1) Slide the leaf manually to the closed position.

2) Rest the first rack element level on the pinion and weld the

support onto the gate as shown in fig. 11.

3) Move the gate manually making sure that the rack rests on

the pinion and weld the remaining supports.

MIN

. 55

MAX. 60

PIANO SUPERIORE
TOP LEVEL

OBERSEITE
DESSUS SUPÉRIEUR

SUPERFICIE SUPERIOR

LATO USCITA PIGNONE
PINION EXIT SIDE
SEITE DES ZAHNZADES
CÔTÉ SORTIE PIGNON
LATO SALIDA PIÑÓN

rif.A

Summary of Contents for 884 mct

Page 1: ...t umweltfreundlich 100 Altpapier pour la nature papier recyclé 100 for nature recycled paper 100 per la natura carta riciclata 100 para la naturaleza 100 papel reciclado C ERME T A Z I E N D A C E R TIF I C A T A UNI EN ISO 9001 085 ...

Page 2: ...em s main switch 12 An omnipower switch shall be provided for the installation with an opening distance of the contacts of 3 mm or more Alternatively use a 6A thermomagnetic breaker with multi pole switching 13 Ensure that there is a differential switch up line of the electrical system with a trip threshold of 0 03A 14 Check that the earthing plant is in perfect condition and connect it to the met...

Page 3: ...ing gate By using a self braking motor the system is guaranteed to be mechanically locked when the motor is not in operation so a lock does not need to be installed The gear motors have adjustable mechanical clutches to ensure correct use of the automation A convenient manual release device allows the gatetobeopenedintheeventofapowerfailureormalfunction The electronic control unit is incorporated ...

Page 4: ... mount the pinion on the transmission shaft and fit the casing provided as shown in fig 6 4 4 MECHANICAL INSTALLATION 1 Remove the casing 2 fig 2 and position the gear motor on the foundation plate Fit but do not tighten the washer the split washer and the nut as shown in fig 7 2 Fit the adjustment screws on the gear motor base as shown in A fig 8 3 Adjust the height of the feet while keeping the ...

Page 5: ... with adequate tripping threshold Connecttheearthcabletotheappropriateseatontheoperator base see fig 20 The operator is equipped with a safety device fig 1 ref 7 activated by the release device If enabled it prevents any manoeuvre by the operator Observing the instructions in Fig 3 lay the raceways and make the electric connections of the 884 T control board to the selected accessories Always sepa...

Page 6: ...3 4 5 6 7 8 9 10 11 12 13 14 15 MOTOR LINE FCA FCC LAMP T1 T2 T3 N L1 L2 L3 400V 3ph N R S T M 3Ph 230 V MOTOR LINE T1 T2 T3 N L1 L2 L3 230V 3ph Fig 15 LED A LED OPEN LED B LED OPEN PARTIALLY CLOSE LED STOP LED STOP LED FSW LED SAFETY DEVICES LED FCC LED CLOSING LIMIT SWITCH LED FCA LED OPENING LIMIT SWITCH SW1 RESET PUSH BUTTON J1 DECODER CONNECTOR J2 LOW VOLTAGE TERMINAL BOARD J3 FAAC LAMP CONNE...

Page 7: ...ave no effect during opening If engaged when the gate is open or pausing closing safety devices prevent its closing To install several safety devices connect the N C contacts in series ÜIf closing safety devices are not connected jumper this input to the common terminal 5 5 Common for commands 6 Common for powering accessories 7 Positive pole for powering 24Vdc accessories Max load of accessories ...

Page 8: ...t GATE STATUS CLOSED OPEN IN PAUSE CLOSING OPENING STOPPED OPEN A OPEN B 1 opens and re closes after pause time 2 re closes after 5 3 reverses motion no effect re closes 2 TABLE 6 LOGIC A2 AUTOMATICA PLUS LOGIC S1 PULSES GATE STATUS CLOSED OPEN IN PAUSE CLOSING OPENING STOPPED OPEN A OPEN B 1 opens and re closes after pause time 2 closes immediately 2 3 reverses motion reverses motion re closes 2 ...

Page 9: ...late a further 10 mm and secure it provisionally on the rack by two weld spots 4 Manually take the gate to closing position leave it 5 cm from the limit stop 5 Allow the plate to slide over the rack in closing direction As soon as the FCC limit switch LED on the 884 T control board fig 13 goes off move the plate a further 10 mm and secure it provisionally on the rack by two weld spots Note The pla...

Page 10: ... A safety microswitch in the release system prevents the automation from being activated by accidental commands 7 fig 2 Close the door and open or close the gate manually 8 RETURN TO NORMAL OPERATION Open the door in the casing using the triangular key provided see fig 24 Move back the lever shown in fig 25 up to the mechanical stop pos AUTOMATIC Close the door 9 MAINTENANCE When performing mainte...

Page 11: ...for sliding gates is an electromechanical operator which transmits movement to the leaf by means of a pinion with rack or chain coupled in an appropriate manner to the sliding gate If automatic operation has been selected sending an impulse causes the gate to reclose on its own after the selected pause time If semiautomatic operation has been selected a second impulse must be sent to reclose the g...

Reviews: