8
Logic E1
Gate Signal
Status Open Stop Reversing
Closed
Opens*
no effect
no effect
Opening Stops
Stops
no
effect
Opened
Closes*
no effect
no effect
Closing Reverses*
Stops
Reverses*
Stopped Closes.
Opens if
reversing
device is
triggered*
no effect
no effect
Logic E2
Gate Signal
Status Open Stop Reversing
Closed
Opens*
no effect
no effect
Opening Stops
Stops
no
effect
Opened
Closes*
no effect
no effect
Closing Reverses* Stops Stops.
Reverses* when
reversing device
no longer
triggered.
Stopped Closes.
Opens* if
reversing
device is
triggered.
no effect
no effect
Logic A1
(This logic mode makes the best use of
reversing devices.)
Gate Signal
Status
Open Stop Reversing
Closed Opens
and
then closes
after timed
pause
no effect
no effect
Opening no effect
Stops
no effect
Opened Closes
after
5 sec pause*
Pause count
is disabled
Pause count is
interrupted until
reversing device
is no longer
triggered*
Closing Reverses
Stops
Reverses
Stopped Closes.
Opens* if
reversing
device is
triggered.
no effect
no effect
Logic A2
Gate Signal
Status Open Stop Reversing
Closed Opens
and
then closes
after pause
time
no effect
no effect
Opening
no effect
Stops
no effect
Opened Closes
after 5 sec*
Pause count
is disabled
Pause count is
canceled. Closes
5 sec after
reversing device
is no longer
triggered.
Closing Reverses
Stops
Stops. Opens
when reversing
device is no
longer triggered.
Stopped Closes.
Opens* if
reversing
device is
triggered.
no effect
no effect
*
If preflashing is selected, gate movement is delayed for an additional 5 seconds.
Marks the responses in gate behavior that differ from the companion operating logic above or