4
Technical Data
Physical dimensions of the
operator case
Length: 7 3/4 in. (195 mm)
Width: 5 1/2 in. (140 mm)
Height: 11 3/8 in. (290 mm)
Power voltage required*
230 VAC, +6 or -10%, 60 Hz*
Built-in control panel
746 MPS, 220 VAC
±
10%, 50–60 Hz
Absorbed power
300 Watts
Amperage draw
1.5 amps
Horsepower rating
1/2 hp
Speed of motor rotation
1400 rpm
Gear ratio
30:1
Operating temperature range
-13 to 158 deg F (-25 to +70 deg C)
Thermal cut out of motor
248 deg F (120 deg C)
Weight, including oil
31 lb (14 kg)
Oil quantity
2.2 qt (2.1 liters)
Oil type
FAAC XD 220 or Shell/Tellus #15
Gate speed
10 in./sec (25.4 cm/sec)
Maximum motor run time**
120 sec
Pulling force***
35 lb (16 kg)
Duty cycles/hour
Depends on gate size but the maximum
motor run time is 50% at 72 deg F
(22 deg C)
Maximum amperage draw for
accessories
360 mA
*
Your standard 220 VAC power source meets the specification for 230 VAC, +6
or -10%.
** If the motor completes its maximum run time, you will have to reset the control
panel for normal operation.
*** The maximum weight pulled at start up assumes nominal voltage (220 VAC) at 72
deg F (22 deg C) and assumes the use of high-quality, lubricated bearing rollers on a
level V track.
Control Panel
You must install the 746 MPS control panel with the 746
Operator. The control panel allows you to set the
following operational controls:
•
Logic: E1, E2, A1, or A2
•
Pause time: 5, 10, 30, or 120 sec
•
5-sec preflashing of attached warning light
In addition, the control panel allows you to easily define
the direction of the gate’s opening direction for the limit
switch and allows you to control the force of the gate’s
movement.
Power supply
: 220 VAC
Operating logic
: E1, E2, A1, or A2
Summary of Contents for 746 ER CAT