background image

9

ENGLISH

ENGLISH

615 AUTOMATIC SYSTEM

The 615 automatic system consists of an aluminium beam
with reflex reflectors, and a steel upright subjected to
cataphoresis treatment and painted with polyester paint.
The upright houses the hydraulic operator and is designed
also to house the electrical control equipment. The operator,
which moves the beam, consists of a hydraulic pump unit
and a double-acting cylinder.

The system is supplied with an adjustable anti-crushing
protection safety device. It also includes a device stopping
the beam in any position, and a manual release command
for use in case of power cuts or faults.

The beam balancing spring and the electronic control unit
(not supplied) must be ordered with reference to the sales
price list.

The 615 automatic system was designed and built for
controlling vehicle access.  Do not use for any other purpose.

1. DESCRIPTION AND TECHNICAL SPECIFICATIONS

1.1.

MAXIMUM USE CURVE

The curve makes it possible to establish maximum work time
(T) according to use frequency (F).
E.g. The 615 automatic system can operate non-stop at a use
frequency of 50%.
To ensure efficient operation, operate in the work range
below the curve.

Important:

 The curve is obtained at a temperature of 20

°

C.

Exposure to the direct sunlight can reduce use frequency
down to 20%.

Calculation of use frequency

The percentage of effective work time (o closing)
compared to cycle total time (o c pause
times).
Calculation formula:

Ot + Ct

%F = 

  X 100

Ot + Ct + Pt + It

where:

Ot

=

opening time

Ct

=

closing time

Pt

=

pause time

It

=

interval time
between a
full cycle and
the next.

foundation plate

barrier upright

electronic equipment
(not supplied)

emergency release

torque adjustment screws

double-acting piston

stroke limit screw

beam

equaliser

oil filling plug

breather screw

balancing spring

spring adjustment tie-rod

hydraulic pump unit

fig.1

10 

1

2

3

5

4

7

8

6

13

12

11

10

9

7

14

TABLE 1Technical specifications of “615 barrier”

BARRIER MODEL

615-1,5 l/min

615-3 l/min

Beam max. length (m)

5

2,5

Max. opening time (sec)

5,7

2,9

Angle  speed (rad/sec)

0.28

0,54

Pump flow-rate (l/min)

1.5

3

Max. torque (Nm)

400

300

Types of beam

Rigid/Skirt

Rigid

Articulated

Use frequency (at 20

°

C)

50%

40%

Max.consecutive cycles (at 

20

°

C

)

220

340

Power supply

230V~ (+6 -10 %) 50Hz

Absorbed power (W)

220

Type of oil

FAAC XD 220

Oil quantity (Kg)

0,9

Winding

120

°

 C

thermal protection

Anti-crushing protection system

standard by-pass valves

Ambient temperature

-20 to +55 

°

C

Hood protective treatment

cataphoresis

Hood paint

Polyester RAL 2004

Protection class

IP 44

Weight (Kg)

34 (sale package)

Upright overall dimensions

270 x 1015 x 140

LxHxD(mm)

Electric motor technical specifications

RPM

1400

2800

Capacity (W)

220

Absorbed current (A)

1

Power supply

230V~  (+6 -10 %) 50Hz

Summary of Contents for 615

Page 1: ...ich 100 Altpapier pour la nature papier recycl 100 for nature recycled paper 100 per la natura carta riciclata 100 para la naturaleza 100 papel reciclado C ERME T A Z I E N D A C E R TIF I C A T A UNI...

Page 2: ...ption of vehicles only systems which however must be provided with signs specifying use for vehicles only Fornon EUcountries toobtainanadequatelevelofsafety theStandards mentioned above must be observ...

Page 3: ...educe use frequency down to 20 Calculation of use frequency The percentage of effective work time opening closing compared to cycle total time opening closing pause times Calculationformula Ot Ct F X...

Page 4: ...fig 3 fig 4 4 3 MECHANICALINSTALLATION 1 Remove the cover provisionally unscrewing the screws securing it to the upright 2 Using the four nuts and washers supplied secure the upright to the foundatio...

Page 5: ...upright 7 Restore normal operation as described in chapter 7 4 5 CONVERTING FROM RIGHT HAND TO LEFT HAND VERSION Procedure for converting a right hand version to left hand Release the operator Loosen...

Page 6: ...witch off power to the system and turn the triangular key clockwise until it stops and then remove it 8 BALANCING SPRINGS The615automaticsystemrequiresabalancingspring which must be ordered separately...

Page 7: ...lug fig 17 andpouroiltoMAX level on the stick Use only FAAC XD 220 oil and no other For repairs contact FAAC s authorised Repair Centres 11 REPAIRS fig 17 fig 15 fig 13 9 AVAILABLE ACCESSORIES SKIRT K...

Page 8: ...er operation is controlled by a electronic control unit housedinanenclosurewithadequatedegreeofprotection against atmospheric agents and which can be housed inside the hood The beam is normally closed...

Page 9: ......

Page 10: ...entepublicaci n todaslasmodificaciones que considere oportunas para el perfeccionamiento t cnico o para cualquier otro tipo de exigencia de car cter constructivo o comercial FAAC S p A Via Benini 1 40...