background image

8

ENGLISH

ENGLISH

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION

(DIRECTIVE 89/392 EEC, APPENDIX II, PART B)

Manufacturer:

FAAC S.p.A.

Address:

Via Benini, 1

40069 - Zola Predosa BOLOGNA-ITALY

Hereby declares
that:

the 615  automation system

• is intended to be incorporated into machinery, or to be assembled with other machinery to constitute

machinery in compliance with the requirements of Directive 89/392 EEC, and subsequent amendments 91/
368 EEC, 93/44 EEC and 93/68 EEC;

• complies with the essential safety requirements in the following EEC Directives:

73/23 EEC and subsequent amendment 93/68 EEC.
89/336 EEC and subsequent amendments 92/31 EEC and 93/68 EEC.

and furthermore declares that unit must not be put into service until the machinery into which it is incorporated
or of which it is a component has been identified and declared to be in conformity with the provisions of
Directive 89/392 EEC and subsequent amendments enacted by the national implementing legislation.

Bologna, 1 January 2000

Managing Director

A. Bassi

IMPORTANT NOTICE FOR THE INSTALLER

GENERAL SAFETY REGULATIONS

1) WARNING! FAAC strongly recommends to follow these instructions

literally for the safety of persons. Improper installation or misuse of the
product will cause very serious damages to persons.

2) Packaging material (plastic, polystyrene etc.) is a potential hazard and

must be kept out of reach of children.

3) Read the instructions carefully before installing the product.

4) Keep these instructions for future reference.

5) This product has been designed and manufactured only for the use stated

in this manual. Any other use not expressly set forth will affect the reliability
of the product and/or could be source of hazard.

6) FAAC S.p.A. cannot be held responsible for any damage caused by

improper use or different from the use for which the automation system is
destined to.

7) Do not use this device in areas subject to explosion: the presence of

flammable gas or fumes is a serious hazard.

8) The system must be constructed in compliance with the following

Standards: EN12604, EN12605, EN12453,EN12445 with the exception of
vehicles only systems which, however, must be provided with signs
specifying use for vehicles only.
For non-EU countries, to obtain an adequate level of safety, the Standards
mentioned above must be observed, in addition to national legal
regulations.

9) FAAC cannot be held responsible for failure to observe technical

standards in the construction of gates and doors, or for any deformation
of the gates which may occur during use.

10) Before carrying out any operations, turn off the system’s main switch.

11) An omnipower switch shall be provided for the installation with an opening

distance of the contacts of 3 mm or more. Alternatively, use a 6A
thermomagnetic breaker with multi-pole switching.

12) Ensure that there is a differential switch up-line of the electrical system,

with a trip threshold of 0.03A.

13) Check that the earthing plant is in perfect condition and connect it to the

metallic parts. Also earth the yellow/green wire of the operator.

14) The automation is fitted with an anti-crush safety system that is a torque

control device. In any case, further safety devices shall be installed.

15) The safety devices (e.g. photocells, safety edges, etc.) protect areas

wherethere is a 

mechanical movement hazard, e.g. crushing, entrapment

and cutting.

16) Each installation must be fitted with at least one fashing light (e.g. FAAC

LAMP, MINILAMP etc) as well as a warning plate suitably fixed to the gate,
besides the safety devices as per point 15. above.

17) FAAC cannot be held responsible regarding safety and correct

functioning of the automation in the event that parts other than FAAC
original parts are used.

18) Use only FAAC original spare parts for maintenance operations.

19)

Do not carry out any modifications to automation components.

20) The installer must supply all information regarding manual operation of the

system in the event of an emergency and provide the end-user with the
leaflet attached to the product.

21) Keep out of persons when the product is in operation.

22) Keep out of reach of children the remote radio controls and any control

devices. The automation could be operated unintentionally.

23) The end-user must avoid any attempt to repair or adjust the automation

personally. These operations must be carried out exclusively by qualified
personnel.

24) What is not explicitly stated in these instructions is not permitted.

Summary of Contents for 615

Page 1: ...ich 100 Altpapier pour la nature papier recycl 100 for nature recycled paper 100 per la natura carta riciclata 100 para la naturaleza 100 papel reciclado C ERME T A Z I E N D A C E R TIF I C A T A UNI...

Page 2: ...ption of vehicles only systems which however must be provided with signs specifying use for vehicles only Fornon EUcountries toobtainanadequatelevelofsafety theStandards mentioned above must be observ...

Page 3: ...educe use frequency down to 20 Calculation of use frequency The percentage of effective work time opening closing compared to cycle total time opening closing pause times Calculationformula Ot Ct F X...

Page 4: ...fig 3 fig 4 4 3 MECHANICALINSTALLATION 1 Remove the cover provisionally unscrewing the screws securing it to the upright 2 Using the four nuts and washers supplied secure the upright to the foundatio...

Page 5: ...upright 7 Restore normal operation as described in chapter 7 4 5 CONVERTING FROM RIGHT HAND TO LEFT HAND VERSION Procedure for converting a right hand version to left hand Release the operator Loosen...

Page 6: ...witch off power to the system and turn the triangular key clockwise until it stops and then remove it 8 BALANCING SPRINGS The615automaticsystemrequiresabalancingspring which must be ordered separately...

Page 7: ...lug fig 17 andpouroiltoMAX level on the stick Use only FAAC XD 220 oil and no other For repairs contact FAAC s authorised Repair Centres 11 REPAIRS fig 17 fig 15 fig 13 9 AVAILABLE ACCESSORIES SKIRT K...

Page 8: ...er operation is controlled by a electronic control unit housedinanenclosurewithadequatedegreeofprotection against atmospheric agents and which can be housed inside the hood The beam is normally closed...

Page 9: ......

Page 10: ...entepublicaci n todaslasmodificaciones que considere oportunas para el perfeccionamiento t cnico o para cualquier otro tipo de exigencia de car cter constructivo o comercial FAAC S p A Via Benini 1 40...