Entering for user setting mode

These functions are used to customize some product functions in the user’s environment.

User Setting Functions

1

Select a desired setting mode by repeated pressing the SET button in standby mode.
Press +/button to enter the selected mode.

SHT-3305XM

These functions enable you to make internal calls when
another monitor or an interphone is installed.

To exit the user setting mode, select 

D.EXIT

, and then press the 

Interphone

button to save your settings. 

In addition, if there is no input for more than 10 seconds, the mode is automatically ended.

Operation

Chapter 

2

-.---.-.-.-----.---.-.-.

---..-.---.-..---.------.--.-

---.----.---.-.-...---.-.

-.-.---.--.-.----.-----.

< USER MODE >

1. DOOR1 MELODY SELECT

1

2. DOOR2 MELODY SELECT

2

3. SLAVE MELODY SELECT

3

4. MELODY VOLUME ADJUST

2

5. ALL IMAGE DELETE

NO

6. FACTORY DEFAULT

NO

7. VIDEO MODE OSD COLOR

RED

8. RTC YEAR ADJUST

2009

9. RTC MONTH ADJUST

01

A. RTC DATE ADJUS

02

B. RTC HOUR ADJUST

03

C. RTC MIN ADJUST

04

D. EXIT

Ver1.0

SHT-3305XM

-.---.-.-.-----.---.-.-.

---..-.---.-..---.----

---.----.---.-.-...---.-.

---..-.---.-..---

1. During the standby mode, press the SET button repeatedlly to select 8.RTC YEAR ADJUST C.RTC MIN

ADJUST.

2. Press the or SET buttons to adjust the desired time.

: Increase the setting value

: Decrease the setting value

SET: Move to the specified item.

(Move to YEAR

MONTH

DAY

HOUR

MIN in turn.)

3. To save the selected settings, press the Interphone button.

SHT-3305XM

-.---.-.-.-----.---.-.-.

---..-.---.-..---.----

---.----.---.-.-...---.-.

---..-.---.-..---

Setting the time

To exit the user setting mode, select 

D.EXIT

, and then press the 

Interphone

button to save your settings. 

In addition, if there is no input for more than 10 seconds, the mode is automatically ended.

If the unit power is off for more than 5 minites, the RTC settings will are reset automatically.

SHT-3305XM

1. While an image is displayed on the screen, press the SET button repeatedlly to select the desired

adjustment mode as below;

TALK VOLUME 2

COLOR STEP 2

CONTRAST STEP 2

BRIGHT STEP 2

EXIT.

2. Press the buttons to select the desired value.

: Increase the setting value

: Decrease the setting value

Each setting can be set up to level 4, and the initial setting value is 2.

3. To save the selected settings, press the Interphone button.

SHT-3305XM

Adjusting the voice volume/screen

To exit the user setting mode, select 

EXIT

, and then press the 

Interphone

button to save your settings. 

In addition, if there is no input for more than 10 seconds, the mode is automatically ended.

SHT-3305XM

-.---.-.-.-----.---.-.-.

---..-.---.-..---.----

---.----.---.-.-...---.-.

---..-.---.-..---

1. During the standby mode, press the SET button repeatedlly to select the desired melody selection item.

(1.DOOR1 MELODY SELECT 3.SLAVE MELODY SELECT)

2. Press the buttons to select the desired melody type as below;

1. Ding-dong 1

2. Ding-dong 2

3. Ding-dong 3

4. Guitar bell 1

5. Guitar bell 2

6. Love’s greeting

7. Tambourine

8. Canon (Pachelbel)

3. To save the selected settings, press the Interphone button.

SHT-3305XM

-.---.-.-.-----.---.-.-.

---..-.---.-..---.----

---.----.---.-.-...---.-.

---..-.---.-..---

Setting the melody type

Melodies can be repeatedly selected for each bell sound of Door 1, Door 2 (Lobby) and Slave (Interphone).

To exit the user setting mode, select 

D.EXIT

, and then press the 

Interphone

button to save your settings. 

In addition, if there is no input for more than 10 seconds, the mode is automatically ended.

Set/select melodies for Door 1, Door 2 (Lobby) and/or Slave (Interphone).

TALK VOLUME 2

Summary of Contents for SHT-330XM/EN

Page 1: ...GC68 00874A ED 01...

Page 2: ...11 Setting the time 11 Deleting all stored images 12 System initialization 12 Supervisor setting Functions Entering for supervisor setting mode 13 Setting the ID 13 Setting the Camera Quantity 14 Set...

Page 3: ...y cause product malfunction electric shock and or fire If the product emits a peculiar noise odor and or smoke immediately lower the circuit breaker connected to the electric heater switch ONT product...

Page 4: ...handset picked up or to make a speakerphone call Micr ophone This is used to make a call with a visitor outside the entrance common entrance or to the interphone Call button This is used to call the h...

Page 5: ...dly press the Call button the entrance hall images are displayed in turn If you press the Call button in standby mode the entrance image is displayed on the screen and a call is connected If you press...

Page 6: ...00 1 2 3 4 5 6 7 8 9 0 HOME INTERPHONE SHT 1100 1 2 3 4 5 6 7 8 9 0 HOME INTERPHONE SHT 1100 1 2 3 4 5 6 7 8 9 0 HOME INTERPHONE SHT 1100 1 If internal calls are not answered for one minute the calls...

Page 7: ...han 10 seconds the mode is automatically ended If the unit power is off for more than 5 minites the RTC settings will are reset automatically SHT 3305XM 1 While an image is displayed on the screen pre...

Page 8: ...1 02 03 04 1 Remove the J1 Jumper on the SHT 3305 s buttom to enter supervisor mode refer to 29 page 2 Press the SET button to select a desired supervisor setting item 3 Press button to select the val...

Page 9: ...time is set 30 seconds door open function is activated talk and monitoring functions are disabled Setting the Camera Quantity SHT 3305XM 1 During the Supervisor setting mode press the SET button repea...

Page 10: ...ime limit on the 9 A DOOR1 2 CALL TIME SET and B SLAVE CALL TIME SET item If a call is not made within the DOOR1 2 s call time limit the visitor s image is recorded stored automatically Setting the Op...

Page 11: ...Interphone button to store your setting SHT 3305XM Setting the Stroge Image Number Set to the number of stroge image SHT 3305XM 1 During the Supervisor setting mode press the SET button repeatedlly to...

Page 12: ...odel press and hold the Open button for more 2 seconds in the standard mode For return to tamper activation after tamper s detection Be sure release to tamper s stop mode and reconnect to camera then...

Page 13: ...f electric shock and fire when connecting AC power or AC Adaptor only for SHT 3305XM AU Be sure turn on the power switch after connecting the power cord or AC Adaptor only for SHT 3305XM AU only for S...

Page 14: ...as shown in the wiring diagram below Wiring Installation Chapter 3 To select slave mode for SHT 3305XM be sure connect to Slave1 perform the following procedure 1 Remove the J1 shunt on the bottom of...

Page 15: ...1 2 ON 1 2 3 1 2 3 Slave 2 ISP Pin1 3 OFF 1 2 3 Slave 1 Interphone3 Interphone2 Interphone1 Door Lock1 Door Lock2 6 5 4 3 2 1 6 5 4 3 2 1 6 5 4 3 2 1 6 5 4 3 2 1 6 5 4 3 2 1 6 5 4 3 2 1 Door Phone1 Do...

Page 16: ...OFF Normal mode Insert Remove Refer to 13 page for only supervise settings W a r n i n g Be sure the multi lobby phone connect to the DOOR2 port The door lock can connect to the doorphone If the door...

Page 17: ...mper 1EA Interphone 1EA Interphone 1EA Interphone SHT IPE200 EN 4 Pin for Door Camera 2 Pin for Camera Door Lock SHT CP611E EN model only Check This First The power does not turn on Make sure if the p...

Page 18: ...5 A 70 g Device SHT IPE200 EN Category Communication Mode Chime Melody Main Unit Electricity Consumption Weight Dimension Specifications Handset Communication Ding Dong Cuckoo Waltz Fur Elise Max 150...

Page 19: ...caused by improper installation and altered serial numbers 3 If you need a warranty service you should send the product to customer Dep t or dealer office the product in all cases must be accompanied...

Reviews: