INSTRUCTION MANUAL
SWD® Starter Kit
Page
17
on
30
V-EN_20072022_SWD® Starter Kit
Charger connector
The Charger connector is a Neutrik XLR 5-pin.
It is used to connect the charger to the battery.
Pin #
Designation
1
2
NC
3
NC
4
NC
5
GND
5.6.
SWD® safety hub
connectors
The SWD® and Scanner connectors of the
SWD® safety hub
follow the pinouts of the above-described
connectors.
Emergency stop connector
The Emergency stop connectors are of type M8 4-pin A coded.
They are used to connect the two normally closed switches of an E-Stop button (2NC type).
Pin #
Designation
1
SW1 NC1
2
SW1 NC2
3
SW2 NC1
4
SW2 NC2
Switch ON and Batt ON connectors
The Switch ON and Batt ON connectors are of type M8 3-pin A coded.
They are used to forward the ON button signal to the activation signal of the battery.
Pin #
Designation
1
SW
3
GND
4
NC
1
5