![Extron electronics IN1604 DT User Manual Download Page 70](http://html1.mh-extra.com/html/extron-electronics/in1604-dt/in1604-dt_user-manual_2457038070.webp)
IN1604 DTP and IN1604 HD Scalers • Configuration Software
64
Assigning EDID
To assign EDID to selected inputs:
1.
From the inputs group box (table of inputs) on the right, select the check boxes for the
desired inputs (see
figure 45
,
8
on page 63).
2.
From the
Favorites
,
Connected Outputs
, or
Available EDID
pane (
4
-
6
) on the
left, select the desired EDID.
3.
From the inputs group box, click the
Assign
button (
9
) to assign EDID to the selected
input or inputs.
To assign EDID to all inputs:
1.
From the
Favorites
,
Connected Outputs
, or
Available EDID
pane (
4
-
6
), select
an EDID.
2.
From the inputs group box, click the
Assign to All
button (
-
).
NOTE:
Checked or unchecked inputs are ignored and the EDID is assigned to all
inputs.
To match the selected inputs to the current output resolution:
Matching the output resolution is the default value for all inputs.
1.
From the inputs group box (table of inputs) on the right, select the check boxes for the
desired inputs (
8
).
2.
In the
Output Resolution
panel, click the
Match Output
button (
7
).
Adding EDID to the EDID Library
1.
Click the
Add EDID to Library
button (
=
). The
Add EDID to Library
window
opens.
2.
Navigate to the desired EDID file location and select it.
NOTE:
Valid EDID files have a .bin file extension.
3.
Click the
Open
button. The EDID is added to the
Available EDID
pane (
6
).
Saving EDID to the EDID Library
1.
From the
Favorites
or
Connected Outputs
pane (
4
-
5
), right-click on an EDID.
2.
Select
Save to EDID Library
.
3.
Click the
OK
button to save the file.
NOTE:
Saving a factory scaler EDID exports an HDMI, LPCM-2Ch EDID to the PC. The
file is saved as a .bin file.