Command and Response Table for SIS Commands (continued)
NOTE:
X2&
= Voltage
Positive or negative voltage and magnitude
X2*
= Temperature
Degrees Fahrenheit
X2(
= Fan speed
In revolutions per minute (RPM)
Command Function
SIS Command
(Host to Unit)
Response
(Unit to Host)
Additional description
Information requests (continued)
Request system status
S
FOX Matrix 3200 Response:
X2&
•
X2&
•
X2&
•
X2&
•
X2&
•
X2&
•
X2&
•
X2*
•
X2(
•
X2(]
FOX Matrix 7200 Response:
X2&
•
X2&
•
X2&
•
X2&
•
X2&
•
X2&
•
X2&
•
X2*
•
X2(
•
X2(
•
X2(
•
X2(]
Response description (
FOX Matrix 3200
):
+3.3V•+5V•+1.3V•+1.2V•+12V (fan volts)•+12V (redundant PS)•+12V (primary PS)•Temp•Fan 1 RPM•Fan 2 RPM
]
Response description (
FOX Matrix 7200
):
+3.3V•+5V•+1.3V•+1.2V•+12V (fan volts)•+12V (redundant PS)•+12V (primary PS)•Temp•Fan 1 RPM•Fan 2 RPM•Fan 3 RPM•Fan 4 RPM
]
Example (
Matrix 3200
):
S
Backplane receiving 12.00 V
Internal temperature 80.6° F
Fan 1 rotating at 3,013 RPM
3.3 V power system at 3.27 V
3.27
•
4.95
•
1.28
•
1.22
•
12.00
•
12.06
•
12.12
•
+080.60
•
03013
•
02860