Command and Response Table for SIS Commands
Symbol Definitions
]
= CR/LF (carriage return/line feed) (hex
0D
0A
)
}
= Carriage return (no line feed, hex
0D
)
|
= Pipe (can be used interchangeably with the
}
character)
• = Space character
E
= Escape key (hex
1B
)
W
= Can be used interchangeably with the
E
character
X!
= Input number (for tie)
00
–
32
(FOX Matrix 3200) or
72
(FOX Matrix 7200) (
00
= untied)
X@
= Output number
01
–
32
(FOX Matrix 3200) or
72
(FOX Matrix 7200)
X#
= Mute
0
= not muted
1
= muted
X$
= SFP or reclockable output number
00
–
32
or
72
(
00
= global [SFP only])
X%
= Output reclocking rate
00
= auto (default)
01
= bypass
X^
= Laser control
0
= disable
1
= enable
2
= automatic
X&
= Global preset #
00
–
32
(3200) or
72
(7200) (
00
= current configuration for view only)
X*
= Room number (for room presets)
01
–
10
maximum (each can have up to 10 presets (
X1)
) assigned)
NOTE:
A Room is a subset of operator‑selected outputs that relate to each other. The FOX matrix switcher supports up to 10 rooms, each
of which can consist of 1 to 16 outputs.
X(
= Name
Up to 12 characters for input and output names and global and room preset names
Upper‑ and lower‑case alphanumeric characters and
_
/
and spaces are valid.
NOTE:
The following characters are invalid or not recommended in the name:
~
,
@
=
‘
[
]
{
}
<
>
’
“
;
:
|
\
and
?
.
X1)
= Room preset number
01
–
10
maximum
NOTE:
A Room preset is a stored configuration with all outputs in a single room. A retrieved room preset becomes the current configuration.
X1!
= Connection status
0
= no input connected
1
= input connected
X1@
= Group number (for I/O grouping)
1
(group 1) through
4
(group 4) (or
0
= no group)
X1#
= Input number (for other than tie)
01
–
32
(FOX Matrix 3200) or
72
(FOX Matrix 7200)
X1$
= Lock mode status
0
= unlocked
1
= locked
X1%
= Number (quantity) of inputs
8
,
16
,
24
,
32
,
40
,
48
,
56
,
64
, or
72
X1^
= Number (quantity) of outputs
8
,
16
,
24
,
32
,
40
,
48
,
56
,
64
, or
72
X1&
= Board installed
0
= No board installed
4
= Non‑pathological multimode board
1
= Non‑reclocking multimode board*
5
= Non‑pathological singlemode board
2
= Non‑reclocking singlemode board*
6
= Pathological singlemode board
3
= 3G, SDI, HD‑SDI board
x
= Unknown board or mix of transceivers
X1*
= I/O board slot number
1
–
9
(FOX Matrix 7200) or
1
–
4
(FOX Matrix 3200)
X1(
= Transceiver module installed
0
= No module installed
1
= Non‑pathological multimode module
3
= 3G‑SDI, HD‑SDI, SD‑SDI module
2
= Non‑pathological singlemode module
4
= Pathological singlemode module
X2)
= Transceiver module number
01
–
72
(or maximum number of transceiver modules for your configuration)
X2!
= Vendor/manufacturer name
X2@
= Transmit output power in milliwatts
X2#
= Receive optical power in milliwatts
X2$
= SFP temperature
Degrees Celsius
X2%
= Firmware version number to second decimal place (x.xx)
X2^
= Verbose firmware version‑description‑upload date/time. See the Query controller firmware version (verbose) command on
page 65
.
X2&
= Voltage
Positive or negative voltage and magnitude
X2*
= Temperature
Degrees Fahrenheit
X2(
= Fan speed
In revolutions per minute (RPM)
* Legacy board, no longer manufactured, identified for completeness only
X1)
= Output rate:
nnnn
= actual rate (in MHz)
0000
= no connection or rate
mismatch
‑ ‑ ‑ ‑ = bypass mode
X2@
= Reclocking status
0
= Signal reclocked
1
= Signal not reclocked
X2@
= Reclocking status
0
= Signal reclocked
1
= Signal not
reclocked
FOX Matrix 3200 and 7200 Switchers • Programming Guide
58
Summary of Contents for FOX Matrix 3200