Command and Response Table for SIS Commands (continued)
Command Function
SIS Command
(Host to Unit)
Response
(Unit to Host)
Additional description
Information requests
Information request
I
V
X1%
X
X1^
•
A
X1%
X
X1^
•
S
X1&
1
X1&
2
...
X1&
n
]
V
X1%
X
X1^
shows the number of available inputs
and outputs for this configuration.
A
X1%
X
X1^
has no meaning for this product.
S
X1&
1
X1&
2
...
X1&
n
shows the board type installed
in each slot.
n
is either 4 or 9, depending on the model.
Slot/plane/LC information
0*
X1*
I
X1(
1
X1(
2
X1(
3
X1(
4
X1(
5
X1(
6
X1(
7
X1(
8
]
Request part number
N
68-
nnnn
-
nn
]
See
www.extron.com
, for part numbers.
Request part number and
board configuration
*N
68-
nnnn
-
nn
.
X1&
1
X1&
2
X1&
3
...
X1&
n
]
Part number (see below) plus I/O boards installed.
n
is either 4 or 9, depending on the model.
Read reclocker status
X$
=
X%]
Show current rate status for reclocker
X$
.
NOTE:
The switcher automatically detects and reclocks the signal if the rate is 4.25 Gbps only. Other rates are ignored.
View SFP module status
40*
X2)
S
X2!
•
X2@
•
X2#
•
X2$]
NOTE:
There are up to three separate sets of Extron firmware on which the switcher can report: the controller firmware, which is the
overall control firmware; the Ethernet protocol firmware, which handles the Ethernet interface; and the latest optional Extron firmware
update, which is available at
www.extron.com
.
Query firmware version
Q
X2%]
Example:
Q
1.23
]
The factory‑installed controller firmware version
is 1.23 (sample value only).
Query controller firmware
version (verbose)
0Q
X2%
-
X2^
-
X2^]
Provide a detailed status of the Ethernet protocol
firmware, the controller firmware, and any
firmware upgrade. The firmware that is
running is marked by an asterisk (
*
). A caret
(
^
) indicates that the firmware has a bad
checksum or an invalid load.
?
.
??
indicates
that firmware is not loaded.
Response description:
Ethernet protocol firmware version‑controller firmware version‑updated firmware version
]
Example:
0q
Ethernet
protocol
firmware
Description
Fiber Matrix firmware version
Updated firmware version
* indicates the version running
Upload date and time
1.23
-
1.00(1.68-FOMX
Series
-
Wed,
20
Feb
2008
00:00:00
GMT)
-
1.00*(1.06-FOMX
Series
-
Mon,
17
Mar
2007
16:39:21
GMT)
NOTE:
X1%
= Number (quantity) of inputs
8
,
16
,
24
,
32
,
40
,
48
,
56
,
64
, or
72
X1^
= Number (quantity) of outputs
8
,
16
,
24
,
32
,
40
,
48
,
56
,
64
, or
72
X1&
= Board installed
0
= No board installed
4
= Non‑pathological multimode board
1
= Non‑reclocking multimode board
5
= Non‑pathological singlemode board
2
= Non‑reclocking singlemode board
6
= Pathological singlemode board
3
= 3G, SDI, HD‑SDI board
X
= Unknown board or mix of transceivers
X1*
= I/O board slot number
1
–
9
(FOX Matrix 7200) or
1
–
4
( FOX Matrix 3200)
X1(
=
Transceiver module installed
0
= No module installed
1
= Non‑pathological multimode module
3
= 3G‑SDI, HD‑SDI, SD‑SDI module
2
= Non‑pathological singlemode module
4
= Pathological singlemode module
X2)
= Transceiver module number
01
–
72
(or maximum number of transceiver modules for your configuration)
X2!
= Vendor/manufacturer name
X2@
= Transmit output power in milliwatts
X2#
= Receive optical power in milliwatts
X2$
= SFP temperature
Degrees Celsius
X2%
= Firmware version number to second decimal place (x.xx)
X2^
= Verbose firmware version‑description‑upload date/time. See above.
X%
= Output reclocking rate
00
= Bypass mode
01
= Automatic mode (HDSDI boards only)
03
= 2.125 Gbps (laser boards only)
02
= 1.250 Gbps (laser boards only)
04
= 4.250 Gbps (laser boards only)
X$
= SFP or reclockable output number
00
–
32
or
72
(
00
= global [SFP only])
FOX Matrix 3200 and 7200 Switchers • Programming Guide