DVS 510 Series • Remote Configuration and Control
65
Command
ASCII Command
(Host to Scaler)
Response
(Scaler to Host)
Additional Description
Presets (continued)
Input Presets
Recall input preset
2
*
X2^
.
2
Rpr
X2^
]
Recall input preset
X2^
.
Save input preset
2
*
X2^
,
2
Spr
X2^
]
Save the parameters of the current input
to preset
X2^
(for saved parameters, see
symbol definition on
page 55).
Input Preset Name
Write preset name
E
X2^
,
X1$
NP
}
Nmp
X2^
,
X1$
]
Set name of preset
X2^
to
X1$
. The
command character is a comma. Presets
can have up to 16 characters.
NOTE:
The following characters are invalid in input preset names:
~ @ = ` [] {} <> ’ ‘ “ ” ;
(semicolon)
:
(colon)
| / \ ?
and space.
View preset name
E
X2^
NP
}
X1$
]
View the name of input preset
X2^
.
NOTE:
To clear an input preset name, enter one space character for
X1$
.
Auto Memories
Enable
E
1
AMEM
}
Amem
1
]
Enable auto memories to automatically
recall the previous settings for the
incoming signal (default).
Disable
E
0
AMEM
}
Amem
0
]
Disable auto memories. Input presets
must be manually recalled to configure
the input.
View setting
E
AMEM
}
X1)
]
View the status of auto memories.
Advanced Configuration
Test Pattern
Set test pattern
E
X2)
TEST
}
Test
X2)
]
Select test pattern
X2)
.
View test pattern
E
TEST
}
X2)
]
View the current test pattern.
Freeze
Set freeze
1
F
Frz
1
]
Freeze the selected input.
Set freeze
0
F
Frz
0
]
Unfreeze the selected input.
View
F
X1)
]
Show the freeze status (
1
= on,
0
= off).
RGB Delay Time
Set RGB delay
E
X3&
VDLY
}
Vdly
X3&
]
Set the time the DVS will delay displaying
the new input to
X3&
.
View setting
E
VDLY
}
X3&
]
View the RGB delay setting.
NOTE:
X1)
= Auto memories or freeze status
0
= disabled,
1
= enabled
X1$
= Input preset name
Up to 16 characters; no special characters
X2)
= Test pattern
0
through
13
symbol definitions on page 53.
X2^
= Input preset number
1
through
128
X3&
= RGB delay amount
0
through
50
in 0.1-second increments. Default is
05
(0.5 seconds)