DVS 510 Series • Operation
42
DVS 510 Series Reset Mode Summary
Mode Activation
Result
Purpose and Notes
Factory Firmwar
e
1
Hold in the recessed
RESET
button while applying power
to the unit.
The DVS reverts to the factory
default firmware for a single power
cycle. Event scripting does not start if
the unit is powered on in this mode.
All user files and settings (such as
drivers, adjustments, and IP settings)
are maintained.
Use mode 1 to revert to
the factory default version
for a single power cycle if
incompatibility issues arise
with user-loaded firmware.
Run and Stop Events
3
Hold in the
RESET
button
for about 3 seconds until the
Power LED blinks once, then
release and press
RESET
momentarily (less than
1 second) within 1 second*.
Mode 3 turns events on or off. If the
events are currently stopped after the
momentary press, the power LED
flashes twice, indicating the starting
of events.
If the events are currently running
after the momentary press, the
Power LED flashes three times
indicating the stopping of events.
Mode 3 is useful for
troubleshooting.
Reset All IP Settings
4
Hold in the
RESET
button
for about 6 seconds until
the Power LED blinks twice
(once at 3 seconds, and
again at 6 seconds). Then,
release and press
RESET
momentarily (for less than
1 second) within 1 second*.
Mode 4 does the following:
•
Enables ARP capability.
•
Sets the IP address
back to factory default
(
192.168.254.254
).
•
Sets the subnet back to the
factory default.
•
Sets the default gateway address
to the factory default.
•
Sets port mapping back to factory
default.
•
Turns DHCP off.
•
Turns events off.
Mode 4 enables you to set IP
address information using ARP
and the MAC address.
Reset to Factory Defaults
5
Hold in the
RESET
button
for about 9 seconds until
the Power LED blinks three
times (once at 3 seconds,
again at 6 seconds, again
at 9 seconds). Then,
release and press
RESET
momentarily (for less than
1 second) within 1 second*.
Mode 5 performs a complete reset
to factory defaults (except the
firmware).
•
Does everything mode 4 does.
•
Clears port configurations.
•
Resets all IP options.
•
Clears all user settings.
•
Clears all files from the unit.
Mode 5 is useful if you want
to start over with configuration
and uploading, and also to
replace events.
*For modes 3, 4, and 5, nothing happens if the momentary press does not occur within 1 second.