![Extron electronics DTP2 R 212 Series User Manual Download Page 56](http://html1.mh-extra.com/html/extron-electronics/dtp2-r-212-series/dtp2-r-212-series_user-manual_2456698056.webp)
DTP2 R 212 Series • SIS Commands
48
Command
ASCII Command
(Host to Switcher)
Response
(Switcher to Host)
Additional Description
Configure Serial Port
Set serial port parameters
EX6&
*
X6*
,
X6(
,
X7)
,
X7!
CP
}
Cpn
X6&
•
Ccp
X6*
,
X6(
,
X7)
,
X7!
]
Read serial port parameters
E
X6&
CP
}
X6*
,
X6(
,
X7)
,
X7!
]
Configure current port timeout
E
0
*
X7@
TC
}
Pti0
*
X7@]
View current port timeout
E
0TC
}
X7@]
Configure global port timeout
E
1
*
X7@
TC
}
Pti1
*
X7@]
View global port timeout
E
1TC
}
X7@]
Set UART start point
E
X7#
MD
}
Pmd
X7#]
Read UART start point
E
MD
}
X7#]
KEY:
X6&
=
Port number:
01
= Remote RS‑232 (SIS‑Host Control)
02
= Unused
03-04
= UART's
3
(display control port; port
2001
) and
4
(Over DTP port; port
2002
)
X6*
= Baud rate:
300
,
600
,
1200
,
1800
,
2400
,
3600
,
4800
,
7200
,
9600
(default),
14400
,
19200
,
28800
,
38400
,
57600
,
115200
; Port 1 is fixed at
9600
.
X6(
= Parity odd,
E
ven,
N
one,
M
ark,
S
pace (Only the first letter is required) – default = None.
X7)
= Data bits
7
–
8
(
8
= default)
X7!
= Stop bits
1
,
2
(
1
= default)
X7@
= Port timeout intervals:
1
(= 10 seconds) –
65000
(default is
30
= 300 seconds = 5 minutes, in 10‑sec. increments)
X7#
= Start point for UART ports, default is
1999
(Rear panel RS‑232 host port =
1999
;
2001
= Display Control RS‑232 port;
2002
= Over DTP port). Available port range is
1024-65534
. Ports are disabled by setting to 0 (if applicable).
Attempting to remap a port to a number already used by another service returns E13.
LAN/IP Configuration and Setup (see also Set IP/Subnet/Gateway (all at once))
Set date and time
E
X7%
CT
}
Ipt
•
X7%]
MM/DD/YY-HH:MM:SS
Query date and time
E
CT
}
X7%]
Set DHCP mode
E
X@
DH
}
Idh
•
X@]
Query DHCP mode
E
DH
}
X@]
Set IP address
E
X7^
CI
}
Ipi
•
X7^]
Default =
192.168.254.254
Query IP address
E
CI
}
X7^]
Query hardware MAC address
E
CH
}
X7&]
Set subnet mask
EX7*
CS
}
Ips
•
X7*]
Default =
255.255.0.0
Query subnet mask
E
CS
}
X7*]
Set gateway IP address
E
X7^
CG
}
Ipg
•
X7^]
Default =
0.0.0.0
Query gateway IP address
E
CG
}
X7%]
Set DNS server IP address
E
X7^
DI
}
Ipd
•
X7^]
Default =
0.0.0.0
KEY:
X@
= Status:
0
= Off
1
= On
X7%
= Set Date/Time
(
MM/DD/YY-HH:MM:SS
); Example:
06/21/20-10:54:00
X7^
= IP Address (
xxx.xxx.xxx.xxx
):
Leading zeros in each of the 4 fields are optional in setting values and are expressed in
returned values. Factory Default IP address:
192.168.254.254
;
Default Gateway IP addre
ss:
0.0.0.0
,
Default DNS Server UP address:
0.0.0.0
X7&
= Hardware ( MAC) address
(
00-05-A6-##-##-##
)
X7*
= Subnet mask (
xxx.xxx.xxx.xxx
):
Leading zeros in each of the 4 fields are optional in setting values and are expressed in
returned values. Default subnet mask =
255.255.0.0
Summary of Contents for DTP2 R 212 Series
Page 2: ...Safety Instructions...
Page 6: ......