DTP T EU 332, DTP T EU 232, DTP T MK 332, and DTP T MK 232 • Remote Control
20
Error responses
When the switcher receives a valid SIS command, it executes the command and sends a
response to the host device. If the switcher is unable to execute the command because the
command is invalid or it contains invalid parameters, the switcher returns an error response
to the host. The error response codes are:
E01
— Invalid input channel number (out of range)
E06
— Invalid channel change
E10
— Invalid command
E13
— Invalid parameter
Timeout
Pauses of 10 seconds or longer between command ASCII characters result in a timeout.
The command operation is aborted with no other indication.
Using the Command and Response Table
The
command and response table
begins page 22. Symbols are used throughout the
table to represent variables in the command and response fields. Command and response
examples are shown throughout the table. The ASCII to HEX conversion table below is for
use with the command and response table.
ASCII to Hex Conversion Table
•
Space