DTP T EU 332, DTP T EU 232, DTP T MK 332, and DTP T MK 232 • Remote Control
21
Symbol definitions
]
= Carriage return/line feed
}
= Carriage return (no line feed)
|
= Pipe (can be used interchangeably with the
}
character)
•
= space
E
= Escape key
W
= Can be used interchangeably with the
E
character
X!
= Input number (for switching)
0
= No input
1
= HDMI input
2
= VGA input
X@
= Switch mode
0
= Manual
1
= Auto switch VGA (
default
)
2
= Auto switch HDMI
X#
= Input number (for audio configuration)
0
= Always output
1
= HDMI input
2
= VGA input
X$
= Status
0
= Off, disabled, not detected
1
= on, enable, or detected
X%
= Input HDCP status
0
= No source is detected
1
= Source is detected with HDCP
2
= Source detected without HDCP
X^
= Output HDCP status
0
= No sink is detected
1
= Sink is detected with HDCP
2
= Sink is detected without HDCP
X&
= Color bit depth mode
0
= Auto
1
= 8-bit
X*
= EDID
See the
table
on page 23.
X(
= User EDID location
66
or
67
X1)
= Raw EDID data
128 or 256 bytes of hexadecimal data
X1!
= Resolution and rate in plain text
Example:
1920x1200
•
@60Hz
X1@
= Switch position
0
= DTP
1
= HDBT
X1#
= Pixel phase
00
–
63
(
32
=
default
)
X1$
= Total pixels
Depends on input rate
X1%
= Horizontal and vertical start
000
–
255
(
128
=
default
)
X1^
= Switcher name
A text string of up to 24 alphanumeric characters and minus sign/hyphen (-).
No blank or space characters are permitted as part of a name.
The first letter must be a letter, and the last character must not be a minus sign/hyphen.
X1&
= Firmware version number to second decimal place
(x
.
xx
)
X1*
= Verbose mode
0
= clear/none
1
= verbose mode (default for RS-232 or USB) (
default
)
2
= tagged responses for queries
3
= verbose mode and tagged for queries