Figure 3.
DMS 1600 Switcher Rear Panel
ANAHEIM, CA
RESET
RS232/RS422
REMOTE
LAN
ACT LINK
REDUNDANT
PRIMARY
PRIMARY POWER SUPPLY
REDUNDANT POWER SUPPLY
FAN ASSIMBLY
FAN ASSIMBLY
100-240V
50/60Hz
1.2A MAX.
100-240V
50/60Hz
1.2A MAX.
DISCONNECT BOTH POWER
CORDS BEFORE SERVICING
1 - 4
5 - 8
9 - 12
13- 16
17 - 20
21 - 24
25 - 28
29- 32
33 - 36
A
B
DVI-D INPUTS
DVI-D OUTPUTS
C
D
A
B
C
D
A
B
DVI-D INPUTS
DVI-D OUTPUTS
C
D
A
B
C
D
A
B
DVI-D INPUTS
DVI-D OUTPUTS
C
D
A
B
C
D
DVI-D OUTPUTS
A
B
C
D
DVI-D OUTPUTS
A
B
C
D
DVI-D OUTPUTS
A
B
C
D
DVI-D OUTPUTS
A
B
C
D
1
4
6
7
3
5
7
8
2
1 - 4
5 - 8
9 - 12
13- 16
17 - 20
21 - 24
25 - 28
29- 32
33 - 36
Figure 4.
DMS 3600 Switcher Rear Panel
Making Connections
a
DVI-I Input connectors — Connect DVI cables between these ports
and the DVI output ports of the digital video sources.
b
DVI-I Output connectors — Connect DVI displays for the routed
direct digital image.
c
Remote port — If desired, connect a control system or computer
to the rear panel Remote RS-232/RS-422 port.
RS-232 Function
Pin
Function
1
2
3
4
5
6
7
8
9
—
Tx
Rx
—
Gnd
—
—
—
—
Not used
Transmit
Receive
Not used
Ground
Not used
Not used
Not used
Not used
—
Tx–
Rx–
—
Gnd
—
Rx+
Tx+
—
Not used
Transmit (–)
Receive (–)
Not used
Ground
Not used
Receive (+)
Transmit (+)
Not used
RS-422
5
1
9
6
Figure 5.
Audio Output Connector Wiring
d
Ethernet port (LAN connector) — If desired, connect a network
WAN or LAN hub, a control system, or a computer to the Ethernet
RJ-45 port.
Network connection — Wire as a patch (straight-through) cable.
Computer or control system connection — Wire the interface
cable as a crossover cable.
NOTE:
The factory default IP address is 192.168.254.254.
e
Reset button — Initiates four levels of reset of the matrix switcher.
For different reset levels, press and hold the button while the
switcher is running or while you power up the switcher. Refer to
the DMS 1600 and DMS 3600 User Guide, available on the Extron
DVD or at
www.extron.com
.
f
Power connectors — Plug the switcher into two grounded AC
sources.
NOTE:
For reliability, connect the power cord from
the Redundant power connector to either an
uninterruptible power source or to a power source
that is completely independent of the primary power
source.
g
Primary and Redundant power supply indicator LEDs —
Green — Indicates that the associated power supply is operating
within normal tolerances.
Red — Indicates that the associated power supply is operating
outside the normal tolerances or has failed. See
Removing and
Installing a Power Supply Module
to replace the power supply.
h
Fans — See
Removing and Installing a Fan
.
ANAHEIM, CA
RESET
REMO
TE
RS-232/RS-422
LAN
A
CT LINK
100-240V 50/60Hz 1.2A MAX.
100-240V 50/60Hz 1.2A MAX.
REDUND
ANT
PRIMAR
Y
DISCONNECT BO
TH PO
WER
CORDS BEFORE SER
VICING
PRIMARY POWER SUPPLY
REDUNDANT POWER SUPPLY
1 - 4
5 - 8
9 - 12
13 - 16
A
B
DVI-D INPUTS
DVI-D OUTPUTS
C
D
A
B
C
D
DVI-D INPUTS
A
B
DVI-D INPUTS
DVI-D OUTPUTS
C
D
A
B
C
D
DVI-D INPUTS
1
3
4
6
7
5
7
2
8
DISCONNECT BO
TH PO
WER
CORDS BEFORE SER
VICING
1 - 4
5 - 8
9 - 12
13 - 16
RESET
6
DMS 1600 and DMS 3600 • Installation
7
DMS 1600 and DMS 3600 • Installation
Summary of Contents for DMS 1600
Page 20: ...30 DMS 1600 and DMS 3600 Maintenance and Modifications ...
Page 21: ......