AVT 200HD Tuner • Remote Configuration and Control
59
Command/Response Table for IP-Specific SIS Commands
Command
ASCII Command
(Host to Tuner)
Response
(Tuner to Host)
Additional Description
Bidirectional Serial Port
Send data string
EX4!
*
X5&
*
X5*
*
X6!
RS
}
X4@
response
from
command
]
Configure port parameters
24
EX4!
*
X6%
,
X6^
,
X6&
,
X6*
CP
}
Cpn
X4!
•
X6%
,
X6^
,
X6&
,
X6*]
Set baud rate
X6%
, parity
X6^
,
X6&
data bits, and
X6*
stop bits
for port
X4!
.
X6%
= 9600, 19200, 38400, or
115200 (default = 9600)
X6^
= odd, even, none, mark,
or space. (Only the first letter is
required.)
X6&
= Data bits:
7
or
8
(default = 8)
X6*
= Stop bits:
1
or
2
(default =
1
)
View port parameters
EX4!
CP
}
X6%
,
X6^
,
X6&
,
X6*]
Configure flow control
24
EX4!
*
X7)
,
X7!}
Cpn
X4!
•
Cfl
X7)
,
X7!]
Set flow control type
X7)
for
port
X4!
with
X7!
ms between
bytes. For
X7)
:
H
= Hardware
S
= Software
N
= None (default)
X7!
=
0000
through
0001
(default =
0
ms)
View flow control
EX4!
*CF
}
X7)
,
X7!]
Configure receive timeout
24
E X4!
*
X5&
*
X5*
*
X6#
*
X6!
CE
}
Cpn
X4!
•
Cce
X1&
,
X5*
,
X6#
,
X6!
CE
]
NOTE:
X5&
= Time in tens of milliseconds that the AVT will wait until receipt of the first response character before
terminating the command. (Default =
10
= 10 ms; max. = 32767.)
X5*
= Time in tens of milliseconds that the AVT will wait between characters being received via a serial port before
terminating the current command or receive operation. (Default =
20
= 20 ms; max. = 32767.)
X6!
=
#L
or
#D
. The letter parameter is case sensitive (requires capital D or capital L). For
X6!
:
L
= Length of the message to be received,
D
= Delimiter value. A delimiter of ASCII
0A
=
10D
.
#
= Byte count (for L) or a single ASCII character expressed in decimal form (for
D
).
Byte count # can be
0
through
32767
; default = 0. The ASCII decimal # can be
0
through
00255
;
default = the byte count. A 3-byte length =
3
L. The response includes leading zeros.
X6#
= Priority Status for port
X4!
receiving timeouts. For
X6#
:
0
= Use Send data string command parameters (default);
1
= Use Configure receive timeout command parameters. The response includes leading zeros.
View receive timeout
EX!
CE
}
X5&
,
X5*
,
X6#
,
X6!
]
Ethernet Data Port
Set current connection port
timeout
E
0*
X9(
TC
}
Pti0
*
X9(]
Set number of seconds (in tens
of seconds) before timeout on IP
connections.
X9(
=
1
through
32767
.
View current connection port
timeout
E
0TC
}
X9(]
Set global port timeout
E
1
*
X9(
TC
}
Pti1*
X9(]
View global port timeout
E
1TC
}
X9(]