AVT 200HD Tuner • Operation
28
Unit Reset Menu (Resetting from the Front Panel)
Three modes of reset can be initiated from the AVT 200HD front panel.
Next
UNIT
RESET
FACTORY
RESET
PRESS NEXT
TO RESET
Next
Menu
•
FACTORY RESET
•
RESET USER SETTINGS
•
CLEAR CH & PRESET LIST
VIEW
COMM SETTING
Next
RESETTING UNIT
PLEASE WAIT..
Menu
Default
Cycle
Turn either Adjustment knob
to select a reset mode.
Figure 24.
Unit Reset Menu Flow
To reset the unit using the front panel menus:
1.
Press the Menu button repeatedly until
Unit
Reset
is displayed on the LCD screen.
2.
Press Next to go to the Unit Reset submenu.
3.
Rotate either Adjustment knob to display the reset options:
•
Factory
Reset
:
Restores all settings to the defaults that were set at the
factory
except
the IP settings. (This selection is equivalent to the SIS command
E
ZXXX
; see the
Total reset
command in the “Command/response Table for SIS
Commands,” “Remote Configuration and Control” section.)
•
Reset
User
Settings
:
Resets all settings except the scanned channels and presets.
•
Clear
Ch
&
Preset
List
:
Erases scanned channels and presets.
4.
When the desired reset option is displayed on the LCD screen, press Next. The LCD
screen displays
Press
Next
to
Reset
.
5.
Press Next to start the reset. While the unit is being reset, the LCD screen displays
Resetting
Unit
Please
Wait
.
When the reset is complete, the LCD display returns to the default cycle if the channel
list has not been removed. If the channel list has been deleted, the
[Source]
Channel
List
Empty
and
Press
Up
Button
to
Start
Scan
messages alternate on the LCD
screen.
NOTE:
You can perform resets using:
•
The Reset button (see “
Resetting from the Rear Panel
,” later in this
section)
•
SIS commands (see the
Resets
commands in the “Remote Configuration
and Control” section)
•
The Windows-based control software (see the program help file)