3. Change the chassis name by completing the following steps.
a)
Enter
configure terminal
to enter global configuration mode.
b) Enter
switch-attributes
chassis-name
chassis-name
, where
chassis-name
is the new chassis name.
c)
Enter
exit
to return to privileged EXEC mode.
d) To verify the new chassis name, enter the
show chassis
command.
4. Change the host name by completing the following steps.
a)
Enter
configure terminal
to enter global configuration mode.
b) Enter
switch-attributes
host-name
host-name
, where
host-name
is the new host name.
c)
Enter
exit
to return to privileged EXEC mode.
d) To verify the new host name, enter the
show running-config | include host
command.
5. Record the new names for future reference.
Configuring the DNS service
To view the current DNS configuration, enter the
show ip dns
command. To manually configure a unique domain name for your device,
complete the following steps.
1. Log in to the device using one of the following methods:
•
A serial console connection to the active management module. The active management module has the LED labeled
ACTIVE on the front panel illuminated in blue.
•
A Telnet session using the chassis management IP address.
2. Log in to the device using
admin
as your login name. If you have not changed the default password, use
password
for
password.
3. Enter the
ip dns domain-name
domain-name
command, where
domain-name
is the domain name for your device.
4. (Optional) Enter
ip dns name-server
ip-address
, where
ip-address
is the IP address of the DNS server.
Verifying correct operation
Perform the following steps to verify correct operation of the device.
1. Check the LEDs of all power supplies, fans, and modules to verify that all are functional. For a more detailed description of the
LEDs on each system component, refer to
on page 77.
2. Log into the device using one of the following methods:
•
A serial console connection to the active management module. The active management module has the LED labeled
ACTIVE on the front panel illuminated in blue.
•
A Telnet session using the chassis management IP address.
3. Log in to the device using
admin
as your login name. If you have not changed the default password, use
password
for
password.
Verifying correct operation
ExtremeSwitching SLX 9030 Hardware Installation Guide
9035691-02 Rev AD
61
Summary of Contents for EN-SLX-9030-48S-4C
Page 6: ...ExtremeSwitching SLX 9030 Hardware Installation Guide 6 9035691 02 Rev AD...
Page 10: ...ExtremeSwitching SLX 9030 Hardware Installation Guide 10 9035691 02 Rev AD...
Page 64: ...ExtremeSwitching SLX 9030 Hardware Installation Guide 64 9035691 02 Rev AD...
Page 76: ...ExtremeSwitching SLX 9030 Hardware Installation Guide 76 9035691 02 Rev AD...
Page 82: ...ExtremeSwitching SLX 9030 Hardware Installation Guide 82 9035691 02 Rev AD...
Page 96: ...ExtremeSwitching SLX 9030 Hardware Installation Guide 96 9035691 02 Rev AD...