6
3111001 Xzense UK 20190731
Product information
2.
Setup
2.1. Mounting
Sending signals
Place the Power Unit on the chimney so that the most direct line can be reached.
The Power Unit and the chimney fan must have a maximum distance of 1 meter, so that the
cables can reach.
Range
The range between the units should not exceed 18 meters if you want the most optimal
signal. Please note that some constructions may have the smallest scope, including storey
buildings, concrete and steel buildings.
Signal
The repeater makes it possible to obtain a signal if there is too much distance
between the control panel and the Power Unit or if the signal has to pass through, for
example, several storeys.
The signal can at most go through 3 pcs. repeater between an Xzense Power Unit and a
control panel. The repeater is placed between the Xzense control panel and the Power Unit,
which is typically mounted on the chimney.
In some situations, it would be appropriate to set up the repeater outdoors, e.g. under the
overhang or on another building. The signal may have difficulties penetrating certain
materials, such as steel and aluminum structures.
Mounting of sensor and Power Unit
Step
Action
Illustration
1a
Install the sensor on the chimney fan with the
supplied bracket. Drill 2 pcs. 4 mm holes and insert
the screws.
RSV
RS
1b
Mounting with cover flange:
Remove the plug from the tube
cover flange, and insert
sensor. Tighten the screw (A).
(A)
(A)
2a
For brick chimneys:
Drill holes as shown (max. 1 m from the chimney
fan). Remove the lid from the power unit and
mount it on the chimney using rawlplugs and
screws.
Note: Position the device where it has the best line
of sight to the control panel.
110
9
0