2.9. Refire and Afterrun
Step
Action
Display
1
When it’s time to refuel, the display lights up, a small
alarm sounds and a dialog pops up and asks if you
want to refire.
It is possible to turn on the alarm signal in the menu
Settings
.
Det er tid til at genfyrer.
Vil du genfyre nu?
JA
NEJ
It is time to re-fire.
Would you like to re-fire now?
YES
NO
2
If you want to
Refire
, press
YES
in the dialog box before
refire.
In order to avoid soot and smoke in the room, the
chimney fan speed is increased to maximum (boost)
for 3 minutes before falling back to the previous
setting.
3
If you do not want to re-fire,
NO
is
selected and the
Afterrun
will start.
The afterrun has a factory setting of 30 minutes.
30
min
2.10. Turn off the chimney fan
Step
Action
A
Manual: The chimney fan is switched off by pressing the switch off.
Note: If the temperature sensor is activated, the chimney fan cannot be switched off as long as the temperature at
the chimney fan is higher than the stop temperature setting.
B
Automatic: After the last refiring, the temperature in the chimney falls slowly. If the temperature sensor is add the
chimney fan automatically stops when the temperature in the chimney has fallen below the stop temperature.
The factory setting is 35 °C.
The chimney fan has a Afterrun period of 30 minutes, which ensures that the fuel is glow-free and that the remaining
smoke has been led away from the chimney. Both the stop temperature and the afterrun period can be changed in
the menu.