Multimeter Tests
Copper and G.fast/VDSL2/ADSL2+ Multi-play Test Set
137
Isolation
Continuous
The
Continuous
function measures each pair,
displaying and updating results in
real time
, until you
stop the test. The last valid results then remain
displayed. Remember that the continuous application
of a higher voltage tends to dry up moisture in faults,
making it seem as if they have disappeared; but only
the moisture is gone and will likely reappear another
time.
Note:
The test should be run with an open circuit at the far
end.
Note:
If
UFED Control
option is enabled, due to its limitation, the
Continuous
function will act the same as the test in
Snapshot
mode and terminate
after the
Soak Time
period expires.
Current Group
is the current test group name, for example
Multimeter
.
Current Test
displays the test being measured. Here you can switch to
another test from the given list. However, this action will terminate the
ongoing measurement test.
Selected Pair
allows you to select a single wire pair for measurement.
Soak Voltage
allows you to apply a voltage value to the pair(s)
currently under test. Select a value from the list or
User Defined
to
enter your own value. If your unit has the HIVOLT (high voltage)
software option configured, the
Soak Voltage
parameter values are
extended up to 500 V max.
Note:
Since
Soak Voltage
is inherited in other tests that use the
Isolation
test, the
HIVOLT software option also applies to the following tests:
Pair Detective
,
User Auto Test
.
Summary of Contents for MAX-635G
Page 1: ...User Guide Copper and G fast VDSL2 ADSL2 Multi play Test Set MAX 635G www EXFO com ...
Page 10: ......
Page 26: ......
Page 162: ......
Page 218: ......
Page 270: ...TDR 260 MAX 635G Continuous Examples of Common Faults Short Fault ...
Page 271: ...TDR Copper and G fast VDSL2 ADSL2 Multi play Test Set 261 Continuous Open ...
Page 272: ...TDR 262 MAX 635G Continuous Bridged Tap ...
Page 273: ...TDR Copper and G fast VDSL2 ADSL2 Multi play Test Set 263 Continuous Splice Joint ...
Page 274: ...TDR 264 MAX 635G Continuous Peak Function ...
Page 275: ...TDR Copper and G fast VDSL2 ADSL2 Multi play Test Set 265 Continuous Dual Trace View ...
Page 276: ...TDR 266 MAX 635G Continuous Load Coil ...
Page 290: ......
Page 336: ......
Page 414: ......
Page 424: ......
Page 432: ......
Page 438: ......
Page 444: ......