6. Status Menu
6.1.
Introduction
The Status menu provides information about the current status of each item listed below.
6.2.
SFP Status
Item
Description
SFP1-Vendor
These status item display the name of the vendor of the SFP input/output
module A.
SFP1-Type
These status items display the type name/number of SFP input/output
module A.
SFP1-Temp-Stat
These indicate whether the temperature of SFP input/output module A is
Too_High, High, OK, Low or Too_Low. Can also be NA if Temperature
monitoring is not available or the module is not inserted.
SFP1-Volt-Stat
These indicate whether the voltage usage of SFP input/output module A is
Too_High, High, OK, Low or Too_Low. Can also be NA if Voltage monitoring
is not available or the module is not inserted.
Port1-Enabled ~ Port2-
Enabled
This item indicates whether the corresponding output port on the SFP
output module A is enabled, disabled or NA (Not available, when no input
signal is available or an input module is inserted.)
Port1-Power ~ Port2-
Power
These status items indicate the current transmitter power of the specified
port on SFP output module A between 0mW and 6.55mW. When a receiver is
installed or no SFP module is inserted this value is 0.
Port1-Pow-Stat ~ Port2-
Pow-Stat
These indicate whether the output power of the specified port on SFP
output module A is Too_High, High, OK, Low or Too_Low. Can also be NA if
an input module or no module is inserted.
Port1-Bias ~ Port2-Bias
These status items indicate the current laser bias of the specified port on
SFP module A is between 0mA and 300mA. When there is a non fiber SFP or
an input module is inserted, this value will be 0.
Port1-Bias-Stat ~ Port2-
Bias-Stat
These indicate whether the laser bias of the specified port on SFP output
module A is Too_High, High, OK, Low or Too_Low. This can also be NA if
laser bias monitoring is not available or no output module is inserted.
Port1-Wavelength ~
Port2-Wavelength
Indicates the current wavelength of the corresponding output port on the
SFP output module A between 0nm and 2000nm. When there is a non fiber
SFP or RX module installed, this value will be 0.
INSTALLATION AND OPERATION MANUAL
Synapse GMD100 | 6. Status Menu |
19
Summary of Contents for Synapse GMD100
Page 2: ......
Page 8: ......
Page 17: ...Block Schematic INSTALLATION AND OPERATION MANUAL Synapse GMD100 4 The GMD100 Card 9 ...
Page 35: ...9 Block Schematic INSTALLATION AND OPERATION MANUAL Synapse GMD100 9 Block Schematic 27 ...
Page 38: ...30 November 2021 Issue 1 0 C ...
Page 46: ......
Page 47: ......
Page 48: ......