#V_delayA
V-Delay setting allows adjustment of the vertical phase of the output
signal with respect to the selected reference input.
The V-Delay setting gives a delay in addition to the reference timing. For
example: if the V-Delay is set to 10 TV HD lines, the output signal will be
delayed by reference 10 TV HD lines. The signal is delayed
(advanced) with respect to the phase of the reference signal. The
available range is from 0 to a maximum of 1125 lines (dependent on I/O
format). The default setting is 0ln. The preset master for this is Out-Frmt,
hence the # prefix.
#H_delayA
The H-Delay setting allows adjustment of the Horizontal phase of the
output signal with respect to the selected reference input.
The H-Delay setting gives a delay in addition to the reference timing. For
example: if the H-Delay is set to 10 pixels, the output signal will be
delayed by reference 10 pixels. The signal is delayed (advanced)
with respect to the phase of the reference signal. The available range is
from 0 to a maximum of 5124 pixels (dependent on I/O format). The
default setting is 0px. The preset master for this is Out-Frmt, hence the #
prefix.
#F_delayA_AlignA
This setting sets the timecode type to be used for delay alignment.
Default is off. Setting can be set to Off, VITC, ATC or both.
#TC_Align_SetA
The TC_Align_SetA allows correction of the delay of the card according
to the timecode measurement difference of the selected channel A and
B. Modes are Off, Auto, Once and Hold.
When set to Off, the additional delay is set to 0 and the Add-Delay_
Range status is set to OK.
In Auto, the delay continually tracks the difference in timecode of video
channels A and B. The Add-Delay_Range status indicates if the additional
delay is within range.
When set to Once, the delay is set once on the rising edge of this signal
with the difference in timecode of video channel A and B. If you want to
reset the value, the setting must be changed to Hold and then back to
Once.
In Hold the additional delay is fixed and not updated anymore. The Add-
Delay_Range status still indicates if the additional delay is within range.
Hold is often used in combination with Once.
#F_Align_StepA
This setting selects the amount of frames that will be counted before a
frame delay step of the new frame delay is realized. For example, if the
old delay is 100 frames and the new delay is 200 frames and this setting
is set to 2. The new delay increases each frame from 100, 100, 101, 101,
102, 102, etc. until 200. Range is 0fr..1000fr. Default is 0, which results in
an immediate response.
12
| November 2021 | Issue 1.0.C
Summary of Contents for Synapse GMD100
Page 2: ......
Page 8: ......
Page 17: ...Block Schematic INSTALLATION AND OPERATION MANUAL Synapse GMD100 4 The GMD100 Card 9 ...
Page 35: ...9 Block Schematic INSTALLATION AND OPERATION MANUAL Synapse GMD100 9 Block Schematic 27 ...
Page 38: ...30 November 2021 Issue 1 0 C ...
Page 46: ......
Page 47: ......
Page 48: ......