64
WT.050.590.020.DE.IM.0719
Operation
SFC SC
6.
Error
The following table shows and explains possible errors which can
occur. If you are unable to remedy the error yourself, please
contact your contractual partner.
Error
Cause
Remedy
No indication on
device
No power supply
External switch or fuse on
Device fuse defective
Check the power supply and replace
fuse
(Electrician)
Housing cover is fitted incorrectly
Check and, if necessary, fit the
housing cover correctly (cable possibly
trapped)
Positioner/pump does
not work
Positioner in manual mode
Engage manual knob
Dosing device selected incorrectly
Select correct dosing device
Positioner/pump incorrectly
connected
Connect the positioner/pump correctly
(Electrician)
Relay faulty
Test (by an electrician)
Positioner runs in
wrong direction
Positioner incorrectly connected
Correct connections
(Electrician)
Positioner closes
Positioner feedback interrupted
Correct connections
(Electrician)
Digital outputs without
function
Digital inputs not activated
Activate digital inputs
Summary of Contents for WALLACE & TIERNAN SFC SC
Page 1: ...WALLACE TIERNAN MEASURING AND CONTROL SYSTEM SFC SC from version V 3 06 INSTRUCTION MANUAL ...
Page 2: ...2 WT 050 590 020 DE IM 0719 SFC SC Please note Original manual ...
Page 18: ...18 WT 050 590 020 DE IM 0719 Description SFC SC 3 ...
Page 42: ...42 WT 050 590 020 DE IM 0719 Installation SFC SC 5 ...
Page 66: ...66 WT 050 590 020 DE IM 0719 Maintenance SFC SC 7 ...
Page 72: ...72 WT 050 590 020 DE IM 0719 Wiring Diagrams SFC SC 9 ...
Page 73: ...SFC SC Certificats 10 73 10 Certificats ...
Page 74: ...74 WT 050 590 020 DE IM 0719 Certificats SFC SC 10 ...
Page 75: ...SFC SC Certificats 10 75 ...
Page 76: ...76 WT 050 590 020 DE IM 0719 Certificats SFC SC 10 ...