38
WT.050.590.020.DE.IM.0719
Installation
SFC SC
5.
5.3.2
Connect the device to the power supply
Warning!
Only authorized and qualified electricians are permitted to install
the device and open the housing. The unit may only be put into
operation when the housing is closed, and must be connected to
protection earth. Modifications to the device which go beyond
those described in this manual are not permissible.
Warning!
The device is not equipped with a mains switch and is in operation
as soon as the supply voltage is applied. An external switch or
circuit breaker is therefore necessary.
When a local line fuse is used (6 A), the cross-section of the mains
cable must be at least 0.75 mm² (AWG 18).
When connecting system components (e.g. devices, motors,
pumps) and when entering operating data, the system
components must be switched off in order to prevent uncontrolled
activation or any incorrect function.
Caution!
To ensure safe and correct commissioning, knowledge of the
operation, connected electrical load, measurement signals, cable
assignment and fuse protection of the connected devices and
machines and the relevant safety regulations is required.
Commissioning of the unit may therefore only be performed by
qualified and authorized electricians. Incorrectly connected
devices can be damaged, possibly irreparably, or cause faults in
other equipment when they are switched on or in operation.
Ensure that the measuring and control cables are not confused or
make contact with one another. Never connect or disconnect any
cables to which voltage is applied!
Please note
A line-side fuse (max. 16A) in the main supply line is necessary
when connecting to 230 V or 115 V.
Recommendation: Provide an on/off facility for the unit at the
installation site. 6A is recommended for the line fuse.
Observe local installation regulations!
Connect the system components in accordance with the wiring
diagrams (Chapter 9).
Summary of Contents for WALLACE & TIERNAN SFC SC
Page 1: ...WALLACE TIERNAN MEASURING AND CONTROL SYSTEM SFC SC from version V 3 06 INSTRUCTION MANUAL ...
Page 2: ...2 WT 050 590 020 DE IM 0719 SFC SC Please note Original manual ...
Page 18: ...18 WT 050 590 020 DE IM 0719 Description SFC SC 3 ...
Page 42: ...42 WT 050 590 020 DE IM 0719 Installation SFC SC 5 ...
Page 66: ...66 WT 050 590 020 DE IM 0719 Maintenance SFC SC 7 ...
Page 72: ...72 WT 050 590 020 DE IM 0719 Wiring Diagrams SFC SC 9 ...
Page 73: ...SFC SC Certificats 10 73 10 Certificats ...
Page 74: ...74 WT 050 590 020 DE IM 0719 Certificats SFC SC 10 ...
Page 75: ...SFC SC Certificats 10 75 ...
Page 76: ...76 WT 050 590 020 DE IM 0719 Certificats SFC SC 10 ...