IONPURE
®
G2 DISPLAY BOARD – IP-POWERDSP-G2
IP-POWERDSP-G2MAN Rev 1
Page 20 of 25
Figure 19: LOGS Screen
MAX VALUES
: displays maximum values of important parameters to help with
performance analysis and troubleshooting. These values are monitored continuously
while the DC output of the power controller is enabled (closed remote ON/OFF input).
Figure 20: MAX VALUES Screen
VAC
: maximum registered AC input voltage to the selected power controller.
AAC
: maximum registered AC current drawn by the selected power controller.
VDC
: maximum registered DC output volts from the selected power controller to
the CEDI module.
ADC
:
maximum registered DC amps from the selected power controller to the
CEDI module.
Ohms
: maximum registered CEDI module resistance, in ohms. Resistance
values above 996 ohms are represented with “***HI”.
Board temp
:
maximum registered heatsink temperature in degrees Celsius of
the selected power controller.