51
EVINRUDE ICON REMOTE CONTROL SYSTEM
Accessory Power Relay Kit
+
13.25
VDC
Battery Voltage
Battery voltage of 13.25 VDC or higher is required for stable
ICON
network oper-
ation. Inconsistent voltage on the
ICON
network can effect operation.
Use
Evinrude Diagnostics
software “Monitor” screen or a
NMEA 2000
gauge
(
I-Command or ICON
) to monitor voltage. Perform the following steps if
ICON
network voltage is below 13.25 VDC.
Identify which battery is powering the
ICON
network. Test battery connections
and charge. Run the engine connected to the battery for the
ICON
network or
use a battery charger to support the battery voltage.
Visually inspect the 3A fuse for the master power key switch and the 10A fuse
for the power supply cable. Check network voltage at the 10A fuse of the
ICON
power supply cable.
Look for an Accessory Power Relay Kit, P/N 765296, in the
ICON
network. This
(optional) power relay kit connects to one of the 6-port hubs and is required to
power any accessory controlled by the master power key switch.
Connect only the positive lead of an accessory to the terminal board provided
with the accessory power relay kit. Do NOT connect accessory wiring to the
master power key switch.
Summary of Contents for E-tec 2011 Series
Page 1: ......
Page 2: ......
Page 6: ...4...
Page 7: ...5 GENERAL INFORMATION...
Page 14: ...12 NOTES GENERAL INFORMATION...
Page 15: ...13 2011 PRODUCT IMPROVEMENTS...
Page 25: ...23 SERVICE INFORMATION...
Page 41: ...39 EVINRUDE DIAGNOSTICS SOFTWARE...
Page 44: ...42 NOTES EVINRUDE DIAGNOSTICS SOFTWARE...
Page 45: ...43 EVINRUDE ICON REMOTE CONTROL SYSTEM...
Page 55: ...53 I COMMAND...
Page 59: ...57 PARTS AND ACCESSORIES...
Page 62: ...60 NOTES PARTS AND ACCESSORIES...
Page 63: ...61 SERVICE TOOLS...
Page 66: ...64 NOTES TOOLS...
Page 67: ...65 REFERENCE...
Page 84: ...82 NOTES REFERENCE...
Page 85: ...83 APPENDIX...
Page 102: ...100 NOTES APPENDIX...
Page 103: ......
Page 104: ......