TSMIP-10GE Series
IP Transport Stream Monitor
Page-32
Revision 1.0
Note:
This is not possible to enter the TS ID as a hex value.
Num PIDs Expected:
Enter here the number of PIDs expected in the stream (including the null packets if
any), enter zero to disable the test.
Window Measurement
The window measurement values determine at what interval each PID (within the PID List Template)
should be expected before an alarm condition is met.
Window Measurement 1&2 (ms):
Enter a decimal value, measurement is in milliseconds.
Window Measurement 3 (s):
Enter a decimal value, measurement is in seconds.
PID List Template
The PID List Template provides a stream conformance or validation check. Here the user can check the
presence of each PID using one of the Window Measurements as detailed above.
Snapshot Live Stream:
This control is used to populate PID List Window with the PIDs currently found in
the stream. Use of this control is slightly different to most normal operations within VLPro.
•
Upon selecting the Snapshot Live Stream button, the action trigger is automatically executed and
the PID List template Window is refreshed after selecting “OK” in the popup windows.
•
On an operational system ensure to de-select the PID List Template check box before making a
new snapshot, this will avoid alarm conditions being raised as the PID List change.
PID List Template:
Once the PID List Template has been populated and fully configured, this check box
must be checked to activate the PID List Checking. Be sure to check the box once all configuration
changes have been made.
Reset PID Template:
This control is used to reset the PID List. All entries will be set to “NOT SET”, all
Windows measurements (WM) set to “OFF”.