Model 5601MSC
Model 5601MSC Master SPG/Master Clock System
MASTER CLOCK
Revision 2.2
Page - 123
4.4.4.4.9.
Synchronizing the Analog Test Generator Burn In Clock to System Time Immediately
OUTPUT
This menu item allows the user to synchronize the burn in clock for the
analog test generator to system time immediately. This synchronization will
also happen once per day at the time specified using the
Set Jam Time
menu item (see section 4.4.2.2.5).
Caution: This menu item is a live control
.
To synchronize the analog video test generator burn in clock to system time
immediately, select the
Jam Output
menu item and press the
SELECT
button. The left LCD screen will display
TIME JAMMED
in yellow for 2
seconds.
ATG 1
Jam Output
TIME JAMMED
When the time reference is set to VITC or LTC and the frame rate of the time
reference is the same as the SDI output, the time will be jammed directly from
the time reference rather than from system time.
4.4.4.4.10.
Synchronizing all the VITC, LTC, and Burn-In Clocks to System Time Immediately
OUTPUT
This menu item allows the user to synchronize all LTC, VITC, and burn in
clocks (SDI and analog test generators) to system time simultaneously.
Caution
: This menu item is a live control.
To synchronize all the LTC, VITC and TG burn in clocks immediately, select
the Jam all VitcLtc menu item and press the
SELECT
button. The left LCD
panel will display
ALL TIMES JAMMED
in yellow for 2 seconds.
ATG 1
Jam all VitcLtc
ALL TIMES
JAMMED
4.4.4.4.11.
Setting the Analog Video Test Generator Burn in Timecode Frame Offset
OUTPUT
This menu item allows the user to set an offset between the system time
and the analog video test generator burn in time. This feature is commonly
used to compensate for video path delays common within a television
facility. The offset value will be added along with the time zone offset (see
section 4.4.2.2.9) and Daylight Saving Time correction (see section
4.4.2.2.10) to obtain the final VITC time.
To advance the analog video test generator burn in time earlier than the
system time, set the offset to a negative (-) value.
ATG 1
Time offset
0 frames