Model 5600MSC Master Clock/SPG Manual
Page 3-34
Revision 1.6
OPERATION
3.6.5. Configuring the SDI Video Test Generator Output (STG Option only)
3.6.5.1. Selecting the Standard of the SDI Video Test Generator Output
OUTPUT
SDI TEST GEN
STG Standard
STG NTSC-M
STG PAL-B
This menu item sets the output format of the SDI video test generator
output.
3.6.5.2. Setting The Phase of the SDI Video Test Generator Output
The SDI black and test signal outputs will all have the same phase and can be adjusted independent of
the analog colour black and analog and HD SDI test signal outputs. There are four registers that are
used to set the phase of the SDI Test Generator outputs. Figure 3-9 and Figure 3-10 show the default
video sync alignment for 59.94 Hz and 50 Hz systems respectively.
"
The front panel display will show
WARNING LIVE CTL
for 0.6 seconds to indicate
that adjusting the SDI Test Generator output phase menu items will affect the
phasing of the SDI Test Generator output immediately. You do not have to press
the SELECT button to accept the new values. Use these controls with caution, as
they will affect the overall timing of devices connected to the SDI Test Generator
output.
OUTPUT
SDI TEST GEN
STG V Phase
STG vert ph = 1
This menu item is used to set the phase of the video output in lines.
OUTPUT
SDI TEST GEN
STG H Phase
STG hor ph = 1
This menu item is used to set the phase of the video output in samples.
3.6.5.3. Configuring the SDI Video Test Generator On Screen Message Display
The 5600MSC SDI Video Test generator has a programmable 16-character text message that may be
used to display a source identification message or any other information on the screen.
USO