GENERAL
DST RULES
DST Start Week
DST starts wk1
When the
DST date mode
menu is set to
day/week/month
this menu item
allows the user to set week of the month when DST begins. Set the value
to
last wk
when DST starts on the fourth or fifth week of the month
depending on the year. Use the
SHAFT ENCODER
to change the start
week for DST.
When the
DST date mode
menu is set to
day of month
this menu item is not
used.
GENERAL
DST RULES
DST Start Month
DST starts Jan
This menu item allows the user to set month when DST begins. Use the
SHAFT ENCODER
to change the start month for DST.
3.7.6.3. Setting The DST Offset
GENERAL
DST RULES
DST Offset
DST offset 1 hour
This menu item allows the user to set amount of adjustment to be made
when DST is active.
3.7.7. Firmware
Utilities
The Firmware menu item allows you to view the firmware version that is installed in the 5600MSC and
to upgrade the firmware when a new version is released.
3.7.7.1. Viewing the 5600MSC Firmware Version
GENERAL
Firmware
5600MSC Version
V1.6 build 16
This item is used to display the 5600MSC’s firmware version. When you
press the
SELECT
key, the display shows the software version which will be
something like:
V1.6 build 16
3.7.7.2. Upgrading the 5600MSC Firmware
GENERAL
Firmware
Upgrade 5600MSC
Are You Sure?
This item is used to initiate a firmware upload of the 5600MSC main
application firmware. When you press the
SELECT
key you are prompted
to confirm that you really want to upgrade the firmware, as this process will
completely erase the application firmware in the unit. After you have
confirmed that you want to upgrade the firmware, the 5600MSC will reboot
into its firmware upload mode. See section 4.2 for a complete description of
the firmware upgrade procedure.
"
When upgrading the firmware in the 5600MSC, the unit will not output any of the
signals on its sync or test signal output connectors.