a. Strip the power wire ends.
When stranded wires are used, install wire end sleeves and apply a square crimp for optimal fit
into the terminal blocks
b. Push the wires into the terminal blocks. Connect the wires in accordance with the power
supply wiring schematics in
Power supply requirements on page 13
Note:
The connections L1, L2, L3, PE and N are shown on the terminal blocks.
Note:
The Illustration shows a 230 V 1-phase with neutral connection.
9. For the optional EV Ready certified connection
: Connect the wires as follows:
a. Strip the cable blue and brown wires. With stranded (flexible) wiring, use wire end sleeves and
apply a square crimp for optimal fit into the terminal blocks.
b. Push the wires into the terminal blocks.
Wire
Terminal block
Blue
1
Brown
2
10. For the optional Smart Charging
: Connect the network cable as follows:
a. Strip the network cable green and green/white wires. Install wire end sleeves with a ferrule
length of 12-15 mm (0.47-0.60 in) and apply a square crimp for optimal fit into the terminal
blocks.
b. Push the wires into the terminal blocks.
Wire
Terminal block
Green
3
Green/white
4
11.
Pull on each wire to make sure it is correctly connected. The indicators on the terminal blocks must
be in the locked position.
12.
Install the transparent cover as follows:
a. Make sure that the rubber seal is correctly installed on the transparent cover.
b. Install the transparent cover on the wall dock. Make sure no wiring is trapped between the
transparent cover and the wall dock.
c. Install the three Torx bolts M4 x 40 using the T20 bit.
d. Install the slotted screw with a flat-head screwdriver. A tamper-evident seal can be installed on
this screw.
e. If the station will not be installed immediately, install the connector cap on the transparent
cover to protect the electrical contacts.
4.4. Install the charging cable
See the corresponding illustrations in manual B.
EN
4. Installation instructions
20