15
www.euroklimat.it
(1) Reference conditions: performance based on: Condenser air intake temperature 35°C
–
Evaporator water temperature IN/OUT = 12/7°C - Fluid: pure water
–
Condensing coil:
Microchannel
(2) Reference conditions: sound power level in compliance with ISO 3744
–
Sound pressure level (average) at 10-meter distance, unit in a free field on a reflective surface; non-binding
value obtained from the sound power level.
2.4
SAFETY DEVICES
During the design and construction phase, the Manufacturer has included safety devices (active and passive) in keeping with the current
legislation in the country of use. It is necessary to check, in particular, and on ordering the equipment, that the standard fittings or suppliable
options correspond to the requests and usage requirements. Below are the main safety devices installed on the machine.
SAFETY VALVES
Safety valves are installed on the gas circuit upstream and downstream of the compressor (C). Valve
“A”,
high-pressure side,
is always installed on the equipment, while valve
“B”
low pressure is only installed if required by the regulations of the
country of installation. The function of the valves is extremely important because in all abnormal working conditions, or
when there is a risk of damage to people or property, the device opens the opening, the refrigerant comes out of the circuit
and the pressure returns within the safety parameters. It is essential to ensure correct maintenance of the equipment to
allow the valves to be activated properly in the event of an emergency.
2.5
ACCESSORIES
There are various accessories for this equipment, which serve different purposes. To see a complete list of accessories, please refer to the
technical product catalogue, which can be requested from the Manufacturer and directly from the Company’s Sales Office
. This section only lists
the main accessories that substantially change
the machines’
configuration when installed.
ANTI-VIBRATION MOUNTS (Optional accessory)
There are two types of anti-vibration mounts: standard or anti-seismic. The choice obviously depends on the requirements and needs of the
place of installation. Anti-seismic mounts guarantee excellent performance also in places where earthquakes are frequent. The mounts are
supplied separately from the chiller, in assembly kits, since assembly in the factory could result in serious damage during loading/unloading and
transport, mainly due to the uncontrollability of the resulting oscillations. They must be connected to the machine during the installation phase,
immediately before set up.
EKS HE
–
High efficiency
055-2-1 060-2-1 070-2-1 080-4-2 090-4-2 100-4-2 110-4-2 120-4-2 140-4-2 160-4-2 180-6-2
Cooling capacity
(1)
[kW]
167
186
207
231
260
285
333
373
414
479
547
Compressor power input (tot.)
(1)
[kW]
44,4
50,5
57,8
61,9
70,0
79,7
88,8
100,9
115,5
127,2
155,8
Fan power input (total) ST version
[kW]
6,4
7,5
8,7
9,7
11,2
11,2
12,9
15,0
17,4
19,3
21,8
Fan power input (tot.) LN / SL version
[kW]
5,8
6,6
7,6
8,7
9,9
9,9
11,6
13,2
15,2
14,5
19,0
Supply
V/ph/Hz
400/3/50
400/3/50
400/3/50
400/3/50
400/3/50
400/3/50
400/3/50
400/3/50
400/3/50
400/3/50
400/3/50
Total installed power
[kW]
70
80
90
102
113
123
141
159
180
199
238
Maximum absorbed current
Full load
[A]
124
142
161
175
194
211
248
285
323
360
426
Total sound power (ST version)
(2)
[db(A)]
93
93
94
94
94
95
96
96
97
98
97
Total sound pressure (ST version)
(2)
[db(A)]
60
60
61
61
62
62
63
63
64
66
64
Total sound power (LN version)
(2)
[db(A)]
89
89
90
90
90
91
92
92
93
94
93
Total sound pressure (LN version)
(2)
[db(A)]
56
56
57
57
58
58
59
59
60
62
60
Total sound power (SL version)
(2)
[db(A)]
87
87
88
88
88
89
90
90
91
92
91
Total sound pressure (SL version)
(2)
[db(A)]
54
54
55
55
56
56
58
57
58
60
58
STANDARD ANTI-VIBRATION SPRING
MOUNT
ANTI-VIBRATION SEISMIC SPRING
MOUNT